Quantitation of specific binding ratio in 123I-FP-CIT SPECT: accurate processing strategy for cerebral ventricular enlargement with use of 3D-striatal digital brain phantom.

Akihiro Furuta1,2, Hideo Onishi3, Hizuru Amijima4.   

Abstract

This study aimed to evaluate the effect of ventricular enlargement on the specific binding ratio (SBR) and to validate the cerebrospinal fluid (CSF)-Mask algorithm for quantitative SBR assessment of 123I-FP-CIT single-photon emission computed tomography (SPECT) images with the use of a 3D-striatum digital brain (SDB) phantom. Ventricular enlargement was simulated by three-dimensional extensions in a 3D-SDB phantom comprising segments representing the striatum, ventricle, brain parenchyma, and skull bone. The Evans Index (EI) was measured in 3D-SDB phantom images of an enlarged ventricle. Projection data sets were generated from the 3D-SDB phantoms with blurring, scatter, and attenuation. Images were reconstructed using the ordered subset expectation maximization (OSEM) algorithm and corrected for attenuation, scatter, and resolution recovery. We bundled DaTView (Southampton method) with the CSF-Mask processing software for SBR. We assessed SBR with the use of various coefficients (f factor) of the CSF-Mask. Specific binding ratios of 1, 2, 3, 4, and 5 corresponded to SDB phantom simulations with true values. Measured SBRs > 50% that were underestimated with EI increased compared with the true SBR and this trend was outstanding at low SBR. The CSF-Mask improved 20% underestimates and brought the measured SBR closer to the true values at an f factor of 1.0 despite an increase in EI. We connected the linear regression function (y = - 3.53x + 1.95; r = 0.95) with the EI and f factor using root-mean-square error. Processing with CSF-Mask generates accurate quantitative SBR from dopamine transporter SPECT images of patients with ventricular enlargement.

Entities:  

Keywords:  Cerebrospinal fluid mask processing; Evans Index; Normal pressure hydrocephalus

Mesh:

Substances:

Year:  2018        PMID: 29700797     DOI: 10.1007/s12194-018-0459-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  21 in total

1.  Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study.

Authors:  Takashi Yokoi; Hiroyuki Shinohara; Hideo Onishi
Journal:  Ann Nucl Med       Date:  2002-02       Impact factor: 2.668

2.  The specific uptake size index for quantifying radiopharmaceutical uptake.

Authors:  John S Fleming; Livia Bolt; Jennifer S Stratford; Paul M Kemp
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

3.  Conversion of brain SPECT images between different collimators and reconstruction processes for analysis using statistical parametric mapping.

Authors:  H Matsuda; S Mizumura; T Soma; N Takemura
Journal:  Nucl Med Commun       Date:  2004-01       Impact factor: 1.690

4.  Voxel-based analysis of gray matter and CSF space in idiopathic normal pressure hydrocephalus.

Authors:  Kazunari Ishii; Tetsuro Kawaguchi; Kenichi Shimada; Shingo Ohkawa; Naokazu Miyamoto; Tomonori Kanda; Takafumi Uemura; Toshiki Yoshikawa; Etsuro Mori
Journal:  Dement Geriatr Cogn Disord       Date:  2008-03-05       Impact factor: 2.959

5.  Value of quantitative MRI biomarkers (Evans' index, aqueductal flow rate, and apparent diffusion coefficient) in idiopathic normal pressure hydrocephalus.

Authors:  Samuel E S Ng; Angela M S Low; Kok Kee Tang; Y H Chan; Robert K Kwok
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

6.  [125I] beta-CIT-FE and [125I] beta-CIT-FP are superior to [125I] beta-CIT for dopamine transporter visualization: autoradiographic evaluation in the human brain.

Authors:  I Günther; H Hall; C Halldin; C G Swahn; L Farde; G Sedvall
Journal:  Nucl Med Biol       Date:  1997-10       Impact factor: 2.408

7.  Development of Realistic Striatal Digital Brain (SDB) Phantom for 123I-FP-CIT SPECT and Effect on Ventricle in the Brain for Semi-quantitative Index of Specific Binding Ratio.

Authors:  Akihiro Furuta; Hideo Onishi; Kenta Nakamoto
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2017

8.  123I-Ioflupane/SPECT binding to striatal dopamine transporter (DAT) uptake in patients with Parkinson's disease, multiple system atrophy, and progressive supranuclear palsy.

Authors:  A Antonini; R Benti; R De Notaris; S Tesei; A Zecchinelli; G Sacilotto; N Meucci; M Canesi; C Mariani; G Pezzoli; P Gerundini
Journal:  Neurol Sci       Date:  2003-10       Impact factor: 3.307

9.  Optimal ROI setting on the anatomically normalized I-123 FP-CIT images using high-resolution SPECT.

Authors:  Masanari Nonokuma; Yasuo Kuwabara; Kosuke Hida; Tomonobu Tani; Koichi Takano; Kengo Yoshimitsu
Journal:  Ann Nucl Med       Date:  2016-07-20       Impact factor: 2.668

10.  The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation.

Authors:  Piero Calvini; Guido Rodriguez; Fabrizio Inguglia; Alessandro Mignone; Ugo Paolo Guerra; Flavio Nobili
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057

View more
  1 in total

1.  Impact of the cerebrospinal fluid-mask algorithm on the diagnostic performance of 123I-Ioflupane SPECT: an investigation of parkinsonian syndromes.

Authors:  Yu Iwabuchi; Tadaki Nakahara; Masashi Kameyama; Yohji Matsusaka; Yasuhiro Minami; Daisuke Ito; Hajime Tabuchi; Yoshitake Yamada; Masahiro Jinzaki
Journal:  EJNMMI Res       Date:  2019-09-03       Impact factor: 3.138

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.