| Literature DB >> 29700704 |
Mirza Nadeem Ahmad1, Fakher Rafique2, Faisal Nawaz3, Tahir Farooq2, Muhammad Naveed Anjum4, Tajamal Hussain5, Sajjad Hassan2, Madeeha Batool5, Hamad Khalid6, Khurram Shehzad7.
Abstract
Electrically conductive polyorthochloroaniline/chromium nanocomposites (POC/Cr NCs) were prepared by in situ chemical oxidative polymerization of orthochloroaniline in the presence of Cr nanoparticles (Cr NPs). The load percentage of Cr nanofiller was varied in POC matrix to investigate the effect of Cr nanoparticles on the properties of the nanocomposites. The composition, structure, and morphology of POC and its composites were examined by Scanning electron microscopy, Fourier transform infrared spectroscopy, and UV-visible spectroscopic analysis. The antibacterial potential of POC and its composites was evaluated by the disc diffusion method against Escherichia coli and Bacillus subtilis. The results showed the improved antibacterial potential with the increase in the load percentage of nanofiller. The electrical conductivity of polymer and its composites was measured and correlated with the load percentage. The results showed that electrical conductivity of the composites was enhanced with the increase in load percentage of Cr nanoparticles.Entities:
Keywords: Chromium nanoparticles; Conductivity; Nanocomposite; Nanofiller; Polyorthochloroaniline
Year: 2018 PMID: 29700704 PMCID: PMC5919894 DOI: 10.1186/s13065-018-0416-3
Source DB: PubMed Journal: Chem Cent J ISSN: 1752-153X Impact factor: 4.215
Fig. 1Schematic illustration of polymerization of o-chloroaniline
Fig. 2FTIR spectra of a POC, and POC/Cr NCs containing b 1% Ni NPs, c 3% Ni NPs, d 5% Ni NPs, e 7% Ni NPs, f 10% Ni NPs
Fig. 3UV–Visible spectra of a POC, and POC/Cr NCs containing b 1% Ni NPs, c 3% Ni NPs, d 5% Ni NPs, e 7% Ni NPs, f 10% Ni NPs
Fig. 4Size of inhibitory zones versus load percentage of Cr in nanocomposites
Size of inhibitory zones of antibacterial test of the POC/Cr nanocomposites
| Load percentage of nanofiller (%) | Size of inhibitory zones (mm) | |
|---|---|---|
|
|
| |
| 1% | 0.9 | 0.7 |
| 3% | 1.7 | 1.5 |
| 5% | 2.6 | 2.4 |
| 7% | 3.5 | 3.2 |
| 10% | 3.9 | 3.7 |
| POC | 0.2 | 0.2 |
Fig. 5SEM images of a POC and b POC/Cr NCs containing 7% Cr NPs
Electrical conductivity of POC/Cr NCs
| Samples | Electrical conductivitya (S/cm) |
|---|---|
| 1% | 103 |
| 3% | 114 |
| 5% | 150 |
| 7% | 240 |
| 10% | 350 |
| POC | 3 |
a At room temperature
Fig. 6Plot of electrical conductivity versus load percentage of Cr NPs in nanocomposites