Literature DB >> 29699921

Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy with a passive beam: Organ doses in prostate cancer treatment.

Shunsuke Yonai1, Naruhiro Matsufuji2, Keiichi Akahane2.   

Abstract

PURPOSE: The aim of this work was to estimate typical dose equivalents to out-of-field organs during carbon-ion radiotherapy (CIRT) with a passive beam for prostate cancer treatment. Additionally, sensitivity analyses of organ doses for various beam parameters and phantom sizes were performed.
METHODS: Because the CIRT out-of-field dose depends on the beam parameters, the typical values of those parameters were determined from statistical data on the target properties of patients who received CIRT at the Heavy-Ion Medical Accelerator in Chiba (HIMAC). Using these typical beam-parameter values, out-of-field organ dose equivalents during CIRT for typical prostate treatment were estimated by Monte Carlo simulations using the Particle and Heavy-Ion Transport Code System (PHITS) and the ICRP reference phantom.
RESULTS: The results showed that the dose decreased with distance from the target, ranging from 116 mSv in the testes to 7 mSv in the brain. The organ dose equivalents per treatment dose were lower than those either in 6-MV intensity-modulated radiotherapy or in brachytherapy with an Ir-192 source for organs within 40 cm of the target. Sensitivity analyses established that the differences from typical values were within ∼30% for all organs, except the sigmoid colon.
CONCLUSIONS: The typical out-of-field organ dose equivalents during passive-beam CIRT were shown. The low sensitivity of the dose equivalent in organs farther than 20 cm from the target indicated that individual dose assessments required for retrospective epidemiological studies may be limited to organs around the target in cases of passive-beam CIRT for prostate cancer.
Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Carbon-ion radiotherapy; Monte Carlo; Out-of-field dose; PHITS

Mesh:

Year:  2018        PMID: 29699921     DOI: 10.1016/j.ejmp.2018.04.391

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

Review 1.  Medical application of particle and heavy ion transport code system PHITS.

Authors:  Takuya Furuta; Tatsuhiko Sato
Journal:  Radiol Phys Technol       Date:  2021-06-30

Review 2.  Carbon Ion Therapy: A Modern Review of an Emerging Technology.

Authors:  Timothy D Malouff; Anita Mahajan; Sunil Krishnan; Chris Beltran; Danushka S Seneviratne; Daniel Michael Trifiletti
Journal:  Front Oncol       Date:  2020-02-04       Impact factor: 5.738

3.  Effect of protective glasses on radiation dose to eye lenses during whole breast irradiation.

Authors:  Tokiko Nakamura; Shoichi Suzuki; Kyoichi Kato; Napapong Pongnapang; Naoki Hayashi; Chie Kurokawa; Ikuo Kobayashi; Toru Negishi; Tamaki Matsunami
Journal:  J Appl Clin Med Phys       Date:  2020-10-30       Impact factor: 2.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.