Ascending aortic aneurysm repair 44 years after Starr-Edwards caged-ball aortic valve replacement.

Gabrielle E Hatton1, Akiko Tanaka2, Anthony L Estrera2.   

Abstract

We report a case of ascending aortic aneurysm repair and redo aortic valve replacement with a bioprosthesis 44 years after aortic valve replacement with a Starr-Edwards metal caged-ball prosthesis. The patient presented with a moderately stenotic caged-ball valve and a 50-mm ascending aortic aneurysm on a routine follow-up transthoracic echocardiography. We replaced the valve with a bioprosthesis at the time of aortic repair as the patient wished to stop anticoagulation therapy. Intraoperatively, we found that the cloth covering of the cage was nearly completely destroyed.

Entities:  

Mesh:

Year:  2018        PMID: 29697781      PMCID: PMC7675331          DOI: 10.1093/ejcts/ezy161

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  5 in total

1.  Bentall procedure 39 years after implantation of a Starr-Edwards aortic caged-ball-valve prosthesis.

Authors:  Jan D Schmitto; Philipp Ortmann; Aron F Popov; Kasim O Coskun; Hanna Schotola; Martin Friedrich; Christoph H Wiese; Christian Sohns; Suyog A Mokashi; Vassilios N Didilis; Friedrich A Schoendube
Journal:  J Cardiothorac Surg       Date:  2010-03-18       Impact factor: 1.637

2.  Wear of the metallic studs on the composite seat of the 2320 Starr-Edwards aortic valve and its clinical consequences.

Authors:  C A Warnes; C L McIntosh; W C Roberts
Journal:  Am J Cardiol       Date:  1983-11-01       Impact factor: 2.778

3.  Complications due to cloth wear in cloth-covered Starr-Edwards aortic and mitral valve prostheses--and their management.

Authors:  A Shah; M Dolgin; D A Tice; N Trehan
Journal:  Am Heart J       Date:  1978-09       Impact factor: 4.749

4.  Thirty-year results of Starr-Edwards prostheses in the aortic and mitral position.

Authors:  O L Gödje; T Fischlein; K Adelhard; G Nollert; W Klinner; B Reichart
Journal:  Ann Thorac Surg       Date:  1997-03       Impact factor: 4.330

5.  Failure to prevent progressive dilation of ascending aorta by aortic valve replacement in patients with bicuspid aortic valve: comparison with tricuspid aortic valve.

Authors:  Hisayo Yasuda; Satoshi Nakatani; Marie Stugaard; Yuko Tsujita-Kuroda; Ko Bando; Junjiro Kobayashi; Masakazu Yamagishi; Masafumi Kitakaze; Soichiro Kitamura; Kunio Miyatake
Journal:  Circulation       Date:  2003-09-09       Impact factor: 29.690