Literature DB >> 29697597

Epicardial, Biatrial Ablation With Integrated Uni-bipolar Radiofrequency Technology in Stand-alone Persistent Atrial Fibrillation.

Fabrizio Rosati, Claudio Muneretto, Elisa Merati, Gianluca Polvani, Massimo Moltrasio, Claudio Tondo, Antonio Curnis, Manuel Cerini, Alexandre Metras, Gianluigi Bisleri.   

Abstract

OBJECTIVE: Although minimally invasive approaches for surgical treatment of stand-alone atrial fibrillation have gained popularity for the past decade, ablation technology and extensive lesion sets play a major role in the achievement of a successful procedure, especially in presence of persistent and long-standing persistent atrial fibrillation. We evaluated clinical outcomes after totally endoscopic biatrial epicardial ablation of persistent atrial fibrillation with a novel integrated uni-bipolar radiofrequency device.
METHODS: Forty-nine (49) consecutive patients with stand-alone atrial fibrillation underwent right-sided monolateral thoracoscopic surgical ablation with a novel integrated uni-bipolar radiofrequency energy delivery and temperature-controlled technology. Atrial fibrillation was persistent in 13 (26.5%) of 49 and long-standing persistent in 36 (73.5%) of 49 patients. Mean ± SD age was 60.6 ± 10.3 years. Median duration of atrial fibrillation was 74 months. Mean ± SD left atrial diameter was 44.7 ± 4.0 mm.
RESULTS: Epicardial en bloc isolation of all pulmonary veins (box lesion) and additional ablation of the right atrial free wall was successfully performed via minimally invasive approach without any intraoperative and postoperative major complications. Intraoperative entrance and exit block was achieved in 77.5% (38/49) and 91.8% (45/49) of patients, respectively. Mean ± SD ablation time was 16.3 ± 4.8 minutes. No intensive care unit stay was required. Postoperative sinus rhythm was achieved in 93.8% (30/32) patients, and no pacemaker implantation was required. At 13 months, 87.7% (43/49) of patients were in sinus rhythm; 71.4% (35/49) were free from antiarrhythmic drugs and 75.5% (37/49) from oral anticoagulation.
CONCLUSIONS: Integrated uni-bipolar radiofrequency ablation technology showed to be effective for the surgical treatment of atrial fibrillation with a total endoscopic approach. A versapolar suction device with extensive right-left atrial lesion set may further improve outcomes in patients with nonparoxysmal atrial fibrillation.

Entities:  

Mesh:

Year:  2018        PMID: 29697597     DOI: 10.1097/IMI.0000000000000482

Source DB:  PubMed          Journal:  Innovations (Phila)        ISSN: 1556-9845


  3 in total

1.  Association between gene variants and the recurrence of atrial fibrillation: An updated meta-analysis.

Authors:  Tao Jiang; Ya-Nan Wang; Qiang Qu; Ting-Ting Qi; Yun-Dai Chen; Jian Qu
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

2.  Safety and long-term efficacy of thoracoscopic Epicardial ablation in patients with paroxysmal atrial fibrillation: a retrospective study.

Authors:  John Johnkoski; Bryan Miles; Anna Sudbury; Mohammed Osman; Muhammad Bilal Munir; Sudarshan Balla; Mina M Benjamin
Journal:  J Cardiothorac Surg       Date:  2019-11-06       Impact factor: 1.637

Review 3.  Surgical clip closure of the left atrial appendage.

Authors:  Fabrizio Rosati; Gijs E de Maat; Mattia A E Valente; Massimo A Mariani; Stefano Benussi
Journal:  J Cardiovasc Electrophysiol       Date:  2021-08-04       Impact factor: 2.942

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.