Literature DB >> 29697493

Performance of an Automated Versus a Manual Whole-Body Magnetic Resonance Imaging Workflow.

Daniel Stocker, Tim Finkenstaedt, Bernd Kuehn1, Daniel Nanz, Markus Klarhoefer2, Roman Guggenberger, Gustav Andreisek, Berthold Kiefer1, Caecilia S Reiner.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the performance of an automated workflow for whole-body magnetic resonance imaging (WB-MRI), which reduces user interaction compared with the manual WB-MRI workflow.
MATERIALS AND METHODS: This prospective study was approved by the local ethics committee. Twenty patients underwent WB-MRI for myopathy evaluation on a 3 T MRI scanner. Ten patients (7 women; age, 52 ± 13 years; body weight, 69.9 ± 13.3 kg; height, 173 ± 9.3 cm; body mass index, 23.2 ± 3.0) were examined with a prototypical automated WB-MRI workflow, which automatically segments the whole body, and 10 patients (6 women; age, 35.9 ± 12.4 years; body weight, 72 ± 21 kg; height, 169.2 ± 10.4 cm; body mass index, 24.9 ± 5.6) with a manual scan. Overall image quality (IQ; 5-point scale: 5, excellent; 1, poor) and coverage of the study volume were assessed by 2 readers for each sequence (coronal T2-weighted turbo inversion recovery magnitude [TIRM] and axial contrast-enhanced T1-weighted [ce-T1w] gradient dual-echo sequence). Interreader agreement was evaluated with intraclass correlation coefficients. Examination time, number of user interactions, and MR technicians' acceptance rating (1, highest; 10, lowest) was compared between both groups.
RESULTS: Total examination time was significantly shorter for automated WB-MRI workflow versus manual WB-MRI workflow (30.0 ± 4.2 vs 41.5 ± 3.4 minutes, P < 0.0001) with significantly shorter planning time (2.5 ± 0.8 vs 14.0 ± 7.0 minutes, P < 0.0001). Planning took 8% of the total examination time with automated versus 34% with manual WB-MRI workflow (P < 0.0001). The number of user interactions with automated WB-MRI workflow was significantly lower compared with manual WB-MRI workflow (10.2 ± 4.4 vs 48.2 ± 17.2, P < 0.0001). Planning efforts were rated significantly lower by the MR technicians for the automated WB-MRI workflow than for the manual WB-MRI workflow (2.20 ± 0.92 vs 4.80 ± 2.39, respectively; P = 0.005). Overall IQ was similar between automated and manual WB-MRI workflow (TIRM: 4.00 ± 0.94 vs 3.45 ± 1.19, P = 0.264; ce-T1w: 4.20 ± 0.88 vs 4.55 ± .55, P = 0.423). Interreader agreement for overall IQ was excellent for TIRM and ce-T1w with an intraclass correlation coefficient of 0.95 (95% confidence interval, 0.86-0.98) and 0.88 (95% confidence interval, 0.70-0.95). Incomplete coverage of the thoracic compartment in the ce-T1w sequence occurred more often in the automated WB-MRI workflow (P = 0.008) for reader 2. No other significant differences in the study volume coverage were found.
CONCLUSIONS: In conclusion, the automated WB-MRI scanner workflow showed a significant reduction of the examination time and the user interaction compared with the manual WB-MRI workflow. Image quality and the coverage of the study volume were comparable in both groups.

Entities:  

Mesh:

Year:  2018        PMID: 29697493     DOI: 10.1097/RLI.0000000000000471

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

Review 1.  [Artificial Intelligence in radiology : What can be expected in the next few years?]

Authors:  Johannes Haubold
Journal:  Radiologe       Date:  2020-01       Impact factor: 0.635

2.  Multiparametric prostate MRI quality assessment using a semi-automated PI-QUAL software program.

Authors:  Francesco Giganti; Sydney Lindner; Jonathan W Piper; Veeru Kasivisvanathan; Mark Emberton; Caroline M Moore; Clare Allen
Journal:  Eur Radiol Exp       Date:  2021-11-05

Review 3.  Identifying Opportunities for Workflow Automation in Health Care: Lessons Learned from Other Industries.

Authors:  Teresa Zayas-Cabán; Saira Naim Haque; Nicole Kemper
Journal:  Appl Clin Inform       Date:  2021-07-28       Impact factor: 2.342

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.