Literature DB >> 29695391

Recurrence of a totally occluded aneurysm after treatment with a pipeline embolization device.

Felipe Padovani Trivelato1, Alexandre Cordeiro Ulhôa1, Marco Tulio Rezende1, Luis Henrique Castro-Afonso2, Daniel Giansante Abud2.   

Abstract

Treatment with a pipeline embolization device (PED) is widely accepted as an excellent option for patients harboring giant, wide neck, saccular intracranial aneurysms. It has been shown to be safe and very effective. We describe a previously unreported case of a large middle cerebral artery aneurysm, related to the carotid tip, that was treated with a PED and coils. The 6 month follow-up angiogram demonstrated complete occlusion of the aneurysm. However, the 9 month angiogram revealed recurrent filling of the aneurysm sac. To our knowledge, this is the first report to describe recanalization of an aneurysm totally occluded on the control angiography after treatment with a PED. Unanswered questions include the mechanism of recanalization and the need for additional control angiograms and MRI following a previous examination revealing total aneurysm occlusion. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

Entities:  

Keywords:  aneurysm; complication; flow diverter

Mesh:

Year:  2018        PMID: 29695391      PMCID: PMC5926671          DOI: 10.1136/bcr-2018-013842

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  10 in total

Review 1.  Off-label uses of the Pipeline embolization device: a review of the literature.

Authors:  Purvee D Patel; Nohra Chalouhi; Elias Atallah; Stavropoula Tjoumakaris; David Hasan; Hekmat Zarzour; Robert Rosenwasser; Pascal Jabbour
Journal:  Neurosurg Focus       Date:  2017-06       Impact factor: 4.047

2.  Late recurrence of a completely occluded large intracranial aneurysm treated with a Tubridge flow diverter.

Authors:  Xiaoxi Zhang; Nan Lv; Chi Wang; Wei Cao; Jianmin Liu; Qinghai Huang
Journal:  J Neurointerv Surg       Date:  2016-06-24       Impact factor: 5.836

3.  Rapid delayed growth of ruptured supraclinoid blister aneurysm after successful flow diverting stent treatment.

Authors:  Stefan Thomas Lang; Zarina Assis; John H Wong; William Morrish; Alim P Mitha
Journal:  J Neurointerv Surg       Date:  2016-07-28       Impact factor: 5.836

4.  Safety and efficacy of the Pipeline embolization device for treatment of intracranial aneurysms: a pooled analysis of 3 large studies.

Authors:  David F Kallmes; Waleed Brinjikji; Saruhan Cekirge; David Fiorella; Ricardo A Hanel; Pascal Jabbour; Demetrius Lopes; Pedro Lylyk; Cameron G McDougall; Adnan Siddiqui
Journal:  J Neurosurg       Date:  2016-10-28       Impact factor: 5.115

5.  Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial.

Authors:  Tibor Becske; Waleed Brinjikji; Matthew B Potts; David F Kallmes; Maksim Shapiro; Christopher J Moran; Elad I Levy; Cameron G McDougall; István Szikora; Giuseppe Lanzino; Henry H Woo; Demetrius K Lopes; Adnan H Siddiqui; Felipe C Albuquerque; David J Fiorella; Isil Saatci; Saruhan H Cekirge; Aaron L Berez; Daniel J Cher; Zsolt Berentei; Miklós Marosfoi; Peter K Nelson
Journal:  Neurosurgery       Date:  2017-01-01       Impact factor: 4.654

6.  Learning from failure: persistence of aneurysms following pipeline embolization.

Authors:  Maksim Shapiro; Tibor Becske; Peter K Nelson
Journal:  J Neurosurg       Date:  2016-05-06       Impact factor: 5.115

7.  A single pipeline embolization device is sufficient for treatment of intracranial aneurysms.

Authors:  N Chalouhi; S Tjoumakaris; J L H Phillips; R M Starke; D Hasan; C Wu; M Zanaty; D Kung; L F Gonzalez; R Rosenwasser; P Jabbour
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-30       Impact factor: 3.825

8.  Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysms.

Authors:  D Fiorella; P Lylyk; I Szikora; M E Kelly; F C Albuquerque; C G McDougall; P K Nelson
Journal:  J Neurointerv Surg       Date:  2009-06-16       Impact factor: 5.836

9.  Continued growth of and increased symptoms from a thrombosed giant aneurysm of the vertebral artery after complete endovascular occlusion and trapping: the role of vasa vasorum. Case report.

Authors:  Koji Iihara; Kenichi Murao; Nobuyuki Sakai; Akio Soeda; Hatsue Ishibashi-Ueda; Chikao Yutani; Naoaki Yamada; Izumi Nagata
Journal:  J Neurosurg       Date:  2003-02       Impact factor: 5.115

10.  Symptomatic enlargement of an occluded giant carotido-ophthalmic aneurysm after endovascular treatment: the vasa vasorum theory.

Authors:  Amir R Dehdashti; Laurent Thines; Robert A Willinsky; Michael Tymianski
Journal:  Acta Neurochir (Wien)       Date:  2009-04-03       Impact factor: 2.216

  10 in total
  2 in total

1.  Follow-up of Intracranial Aneurysms Treated by Flow Diverters: Evaluation of Parent Artery Patency Using 3D-T1 Gradient Recalled-Echo Imaging with 2-Point Dixon in Combination with 3D-TOF-MRA with Compressed Sensing.

Authors:  J Burel; E Gerardin; M Vannier; A Curado; M Verdalle-Cazes; N Magne; M Lefebvre; C Papagiannaki
Journal:  AJNR Am J Neuroradiol       Date:  2022-03-03       Impact factor: 3.825

2.  Progressive volume reduction and long-term aneurysmal collapse following flow diversion treatment of giant and symptomatic cerebral aneurysms.

Authors:  Kristina Sirakova; Marin Penkov; Svetozar Matanov; Krasimir Minkin; Kristian Ninov; Asen Hadzhiyanev; Vasil Karakostov; Irena Ivanova; Stanimir Sirakov
Journal:  Front Neurol       Date:  2022-08-11       Impact factor: 4.086

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.