Partial Prosthetic Mitral Valve Dehiscence: Transapical Percutaneous Closure.

Catarina Ruivo1, José Ribeiro2, Alberto Rodrigues2, Luís Vouga2, Vasco Gama2.   

Abstract

Entities:  

Mesh:

Year:  2018        PMID: 29694553      PMCID: PMC5898782          DOI: 10.5935/abc.20180028

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


× No keyword cloud information.
An 80-year-old woman with a history of mitral and aortic prosthesis replacement with biological prostheses due to endocarditis presented worsening dyspnea. A transthoracic echocardiogram demonstrated a paravalvular regurgitation between the left ventricle and left atrial appendage. Given her high-risk surgery (EuroSCORE-II: 38%), a percutaneous approach was performed for definitive closure. Transesophageal echocardiography (TEE) peri-procedure allowed the visualization of a partial dehiscence of the mitral prosthesis (Panel A, Figure 1). Through the 3D images, a tunneled defect with wall dissection measuring 12.5 mm of maximum diameter (Panel B, Figure 1) was observed. Using a transapical pathway and collecting three-dimensional (3D) images in real time, a 12 mm Amplatzer septal prosthesis was positioned, occluding the entire defect. The TEE 3D image demonstrated savings of adjacent structures and absence of pericardial effusion during closure. Coronary angiography demonstrated no arterial compromise. A slight residual flow was detected after device implantation (C-F Panels Figure 1).
Figure 1

Panel A: 2D peri-processual transesophageal echocardiography (TEE) shows paravalvular regurgitation (yellow arrow) between left ventricle and left atrial appendage; Panel B: Defect 3D TEE with diameter measurement; Panel C: 3D TEE guiding the guidewire through the defect; Panel D: 3D TEE showing the device (asterisk) through the defect; Panel E: left coronary angiography without vascular involvement after occlusal implant (yellow arrow); Panel F: Light residual flux detected after device deployment (asterisk).

Panel A: 2D peri-processual transesophageal echocardiography (TEE) shows paravalvular regurgitation (yellow arrow) between left ventricle and left atrial appendage; Panel B: Defect 3D TEE with diameter measurement; Panel C: 3D TEE guiding the guidewire through the defect; Panel D: 3D TEE showing the device (asterisk) through the defect; Panel E: left coronary angiography without vascular involvement after occlusal implant (yellow arrow); Panel F: Light residual flux detected after device deployment (asterisk). Paravalvular regurgitation may result from suture dehiscence of the mitral prosthesis. Symptoms of heart failure are an indication for closure. A transapical approach allows direct access to the defect, providing good technical support. The TEE 3D image is essential for guiding the guidewire through the defect, confirming the correct position of the device and relating it to critical structures. The anatomy of the defect and the surrounding structures make this case a challenge, on both imaging acquisition and percutaneous technique
  1 in total

1.  A Unique Case of Mitral Valve Dehiscence Post-mitral Valve Repair Diagnosed Using 3D Transesophageal Imaging.

Authors:  Raj D Patel; Mansoor Ahmad; Harshavardhan Ghadiam; Tinoy Kizhakekuttu
Journal:  Cureus       Date:  2020-01-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.