Saeed Rahimi1, Shahriar Shahi1, Zahra Torabi2, Yashar Rezaie2, Negin Ghasemi1, Somayeh Abolhasani3.
Abstract
INTRODUCTION: This study was designed to determine the effect of Osteon II mineralized bone powder on the surface microhardness of two retrofilling materials: Mineral trioxide aggregate (MTA) and Biodentine (BD). METHODS AND MATERIALS: Each retrograde material was mixed and carried into 30 sterile custom-made plastic cylinders. Half of the samples in each group were exposed to Osteon II. All cylinders were submerged in simulated tissue fluid and incubated at 37°C and 100% relative humidity for 7 days. Surface microhardness values of each study group was attained using Vicker's microhardness test. The data were analyzed statistically using two-way ANOVA and independent t test at a significance level of 0.05.Entities:
Keywords: Biodentine; Bone Graft Materials; Mineral Trioxide Aggregate; Vickers Microhardness Test
Year: 2018 PMID: 29692841 PMCID: PMC5800447 DOI: 10.22037/iej.v13i1.14953
Source DB: PubMed Journal: Iran Endod J ISSN: 1735-7497
Descriptive statistics for Vickers surface microhardness values of the study groups
|
|
|
|
|
|---|---|---|---|
|
| yes | 80.5747 (13.49) | 0.447 |
| no | 99.0480 (19.85) | ||
|
| yes | 26.0433 (4.23) | 0.278 |
| no | 33.3094 (4.38) |
Tests of Between-Subjects Effects-two way ANOVA (Adjusted R Squared=0 .86)
|
|
|
|
|
|
|---|---|---|---|---|
|
| 127.728 | 0.871 | 1 | <001 |
|
| 1440.157 | 0.962 | 1 | <001 |
|
| 364.769 | 0.865 | 1 | <001 |
|
| 16.707 | 0.227 | 0.98 | <001 |
|
| 3.167 | 0.053 | 0.417 | 0.08 |