| Literature DB >> 29687000 |
Qinghua Huang1,2, Fan Zhang3, Xuelong Li4.
Abstract
The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.Entities:
Mesh:
Year: 2018 PMID: 29687000 PMCID: PMC5857346 DOI: 10.1155/2018/5137904
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Figure 1The general flowchart of CAD system.
Figure 2The equivalent ellipse (orange line) of a benign breast lesion.
The performance summary of breast ultrasound CAD system.
| Reference | Dataset | Features | Classifiers | Performance |
|---|---|---|---|---|
| [ | 88 benign | Textural features | ANN (BPNN) | Accuracy: 95.86% |
|
| ||||
| [ | 70 benign | Textural features | SVM | Accuracy: 95.83% |
|
| ||||
| [ | 4254 benign | GoogLeNet | Accuracy: 91.23% | |
|
| ||||
| [ | 135 benign | Boltzmann | Accuracy: 93.4% | |
|
| ||||
| [ | 275 benign | Stacked denoising | Accuracy: 82.4% | |
|
| ||||
| [ | 100 benign | Deep polynomial network | SVM | Accuracy: 92.40% |
The performance summary of liver ultrasound CAD system.
| Reference | Dataset | Features | Classifiers | Performance |
|---|---|---|---|---|
| [ | 50 normal | Textural features | ANN | Accuracy: 98% |
|
| ||||
| [ | 15 normal | Textural features | SVM | Accuracy: 88.8% |
|
| ||||
| [ | 44 cyst | Sparse autoencoder | Accuracy: 90.50% | |
|
| ||||
| [ | 79 normal | VGGNet | FCN | Accuracy: 93.90% |
|
| ||||
| [ | 47 cirrhosis | CNN | SVM | Accuracy: 86.9% |
The performance summary of thyroid ultrasound CAD system.
| Reference | Dataset | Features | Classifiers | Performance |
|---|---|---|---|---|
| [ | 48 benign | Textural features | Decision tree: C4.5 | Accuracy: 94.3% |
|
| ||||
| [ | 10 benign | Textural features | AdaBoost | Accuracy: 100% |
|
| ||||
| [ | 71 benign | GoogLeNet | Accuracy: 99.13% | |
|
| ||||
| [ | 465 normal | CNN (15 convolutional layers) | CNN (4 convolutional layers) | AUC: 0.986 |