| Literature DB >> 29686716 |
Abstract
A cross-sectional study on a pool of undergraduate smokers and nonsmokers (n = 200) was randomly selected from Notre Dame University, Lebanon. The study design is based on a questionnaire about the students' smoking record exposure, cotinine saliva levels, and ventilatory lung function parameters. Despite the nonsmoking policies that have been recently established by universities, diffused smoking stations in proximity to classes and offices still exist, at least in the MENA region. Such an environment still imposes a remarkable effect on certain lung health parameters of nonsmokers exhibiting similar exhaled air per second (FEV1) to smokers with a P value = 0.558 and normal flow of air (TV) with a P value = 0.153. However, the maximum amount of air held in the lungs remained different with respect to sex and smoking status. These results imply a poor performance of nonsmokers mimicking partially the lung health parameters of smokers. It remains a pressing issue to increase awareness concerning the debilitating effects of secondhand smoking.Entities:
Mesh:
Substances:
Year: 2018 PMID: 29686716 PMCID: PMC5857306 DOI: 10.1155/2018/5217675
Source DB: PubMed Journal: J Environ Public Health ISSN: 1687-9805
Figure 1Bar graph represents the percentage of students who showed a variation in their smoking habit and trial as collected from a survey conducted during the spring semester 2015.
The frequency, mean, and standard deviation of TV, VC, FEV1, FEV1/VC with respect to sex. P values are also depicted with 95% confidence interval.
| Sex | Frequency | Mean | Standard deviation |
| 95% confidence interval of the difference | ||
|---|---|---|---|---|---|---|---|
| Lower | Upper | ||||||
| TV | Female | 47 | 0.401 | 0.191 | 0.008 | −.167 | −.0254 |
| Male | 103 | 0.497 | 0.222 | ||||
| VC | Female | 47 | 3.923 | 1.572 | 0.001 | −1.928 | −.769 |
| Male | 103 | 5.272 | 1.834 | ||||
| FEV1 | Female | 47 | 2.850 | 1.950 | 0.391 | −.980 | .387 |
| Male | 103 | 3.146 | 1.964 | ||||
| FEV1/VC | Female | 47 | 0.750 | 0.393 | 0.038 | .008 | .271 |
| Male | 103 | 0.611 | 0.334 | ||||
Figure 2Bar graph representing the mean and standard deviation of TV, VC, FEV1, FEV1/VC with respect to the subjects' smoking status.
P values of the ANOVA test for the combined variables: sex and smoking.
| Parameters | Speed (rpm) |
|---|---|
| TV | 0.042 |
| VC | 0.001 |
| FEV1 | 0.802 |
| FEV1/VC | 0.117 |
P values to test the independence of the lung parameters from sex, smoking, and both variables combined.
| Parameters | Sex | Smoking | Smoking/sex |
|---|---|---|---|
| TV | 0.015 | 0.758 | 0.048 |
| VC | 0.001 | 0.001 | 0.002 |
| FEV1 | 0.627 | 0.896 | 0.77 |
| FEV1/VC | 0.018 | 0.042 | 0.057 |