Literature DB >> 29685709

Tritanium Acetabular Cup in Revision Hip Replacement: A Six to Ten Years of Follow-Up Study.

Hazem A H Hosny1, Ahmed El-Bakoury1, Sreebala C M Srinivasan2, Rathan Yarlagadda3, Jonathan Keenan3.   

Abstract

BACKGROUND: The use of highly porous acetabular components has shown to produce good results in revision acetabular surgery. Their surface characteristics enhance initial fixation and bone ingrowth which are prerequisites for adequate osseointegration. The purpose of this study is to analyze the mid-term to long-term survival, clinical and radiological outcomes using the Tritanium cup (Stryker, Mahwah, NJ) in revision hip surgery.
METHODS: This is a retrospective review of all patients who underwent acetabular revision surgery using "Tritanium revision cup" between April 2007 and November 2010 at our institution. Sixty-two patients were included with a mean age of 67.5 years (32-86). According to Paprosky classification, 10 patients had type I defect, 8 had type IIA, 27 had type IIB, 7 had type IIC, and 10 suffered from type IIIA defect. A Kaplan-Meier analysis was used to determine the survival of the cup. Functional outcomes were assessed using Oxford Hip Score. Plain radiographs were performed to assess implant fixation and osseointegration.
RESULTS: The acetabular cup aseptic survivorship was 98.4% at a mean follow-up of 87.6 months. The mean Oxford Hip Score improved from 14.5 (3-31) preoperatively to 38.5 (12-48) at the final follow-up. Two cups were revised (3.2%): 1 for aseptic loosening and 1 for infection.
CONCLUSION: Tritanium revision acetabular cup has shown excellent mid-term to long-term clinical and radiographic results with low failure rate and minimal complications. Longer term follow-up would be of value to assess the ongoing survival of this implant construct.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Tritanium; highly porous cups; osseointegration; revision hip arthroplasty; uncemented cups

Mesh:

Year:  2018        PMID: 29685709     DOI: 10.1016/j.arth.2018.03.040

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Minimum 2-Year Outcomes of a Novel 3D-printed Fully Porous Titanium Acetabular Shell in Revision Total Hip Arthroplasty.

Authors:  Elyse J Berlinberg; J Abraham Kavian; Mackenzie A Roof; Ittai Shichman; Brett Frykberg; William B Lutes; Erik A Schnaser; Stephen A Jones; Richard W McCalden; Ran Schwarzkopf
Journal:  Arthroplast Today       Date:  2022-10-12

Review 2.  The Diagnosis and Treatment of Acetabular Bone Loss in Revision Hip Arthroplasty: An International Consensus Symposium.

Authors:  Peter K Sculco; Timothy Wright; Michael-Alexander Malahias; Alexander Gu; Mathias Bostrom; Fares Haddad; Seth Jerabek; Michael Bolognesi; Thomas Fehring; Alejandro Gonzalez DellaValle; William Jiranek; William Walter; Wayne Paprosky; Donald Garbuz; Thomas Sculco
Journal:  HSS J       Date:  2021-09-28

3.  In vivo evaluation of osseointegration ability of sintered bionic trabecular porous titanium alloy as artificial hip prosthesis.

Authors:  Xiaowei Bai; Ji Li; Zhidong Zhao; Qi Wang; Ningyu Lv; Yuxing Wang; Huayi Gao; Zheng Guo; Zhongli Li
Journal:  Front Bioeng Biotechnol       Date:  2022-09-14

4.  Comparison of the Primary Stability of Porous Tantalum and Titanium Acetabular Revision Constructs.

Authors:  Nicholas A Beckmann; Rudi G Bitsch; Mareike Schonhoff; Klaus-Arno Siebenrock; Martin Schwarze; Sebastian Jaeger
Journal:  Materials (Basel)       Date:  2020-04-10       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.