Shivani Ahlawat1, Laura M Fayad2. 1. The Russell H. Morgan Department of Radiology & Radiological Science, The Johns Hopkins Medical Institutions, 600 North Wolfe Street, Baltimore, MD 21287, United States of America. Electronic address: sahlawa1@jhmi.edu. 2. The Russell H. Morgan Department of Radiology & Radiological Science, The Johns Hopkins Medical Institutions, 600 North Wolfe Street, Baltimore, MD 21287, United States of America; Department of Oncology, The Johns Hopkins Medical Institutions, 600 North Wolfe Street, Baltimore, MD 21287, United States of America; Department of Orthopaedic Surgery, The Johns Hopkins Medical Institutions, 600 North Wolfe Street, Baltimore, MD 21287, United States of America.
Abstract
OBJECTIVE: To determine the utility of "target sign" on diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC) mapping for peripheral nerve sheath tumor (PNST) characterization. MATERIALS AND METHODS: This IRB-approved, HIPAA-compliant study retrospectively reviewed the MR imaging (comprised of T2- FS, DWI (b-values 50, 400, 800 s/mm2and ADC mapping), and static contrast-enhanced (CE) T1-W imaging) of 42 patients (mean age: 40 years (range 8-68 years), 48% (20/42) females) with 15 malignant PNSTs (MPNSTs) and 33 benign PNSTs (BPNSTs). MPNSTs were histologically confirmed while BPNSTs were histologically-proven or with stable clinical and imaging appearance for at least 12 months. Two radiologists assessed imaging characteristics (size, signal intensity, heterogeneity, perilesional edema or enhancement) and the presence or absence of "target sign," on each sequence. A "target sign" was defined as a biphasic pattern of peripheral hyperintensity and homogeneous central hypointensity. Descriptive statistics are reported. Cohen's κ statistic or interclass correlation coefficient (ICC) were used to evaluate interobserver agreement between two observers. Univariate and multiple logistic regression analysis were performed to identify MRI features with predictive values. RESULTS: MPNSTs were larger than BPNSTs (6.3 ± 2.5 cm vs 3.5 ± -2.1 cm, p = 0.0002), had perilesional edema (87%(13/15) vs 18%(6/33), p < 0.0001), heterogeneous enhancement (71%(10/14) vs 13%(4/31), p = 0.0001) and perilesional enhancement (79%(11/14) vs 18%(6/31), p = 0.0001), respectively. The "target sign" was present in: 24%(8/33) BPNSTs vs 0/15 MPNST on T2-FS (p = 0.26); 39%(13/33) BPNSTs vs 20%(3/15) MPNST on DWI using b-value = 50 s/mm2 (p = 0.5); 55%(18/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 400 s/mm2 (p = 0.002); 48%(16/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 800 s/mm2 (p = 0.005) and 64%(21/33) benign vs 0/15 MPNST on ADC mapping(p < 0.0001). By CE-T1 imaging, 32%(10/31) BPNSTs and 7%(1/14) MPNST had a target sign(p = 0.07). The odds of an MPNST in cases with minimum ADC ≤ 1.0 × 10(-3) mm(2)/s are 150 times higher than in cases with ADC > 1.0 × 10(-3). CONCLUSION: In this explorative study, a "target sign" suggests a benign PNST and is more often visible on DWI using high b-values and ADC maps compared with anatomic sequences.
OBJECTIVE: To determine the utility of "target sign" on diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC) mapping for peripheral nerve sheath tumor (PNST) characterization. MATERIALS AND METHODS: This IRB-approved, HIPAA-compliant study retrospectively reviewed the MR imaging (comprised of T2- FS, DWI (b-values 50, 400, 800 s/mm2and ADC mapping), and static contrast-enhanced (CE) T1-W imaging) of 42 patients (mean age: 40 years (range 8-68 years), 48% (20/42) females) with 15 malignant PNSTs (MPNSTs) and 33 benign PNSTs (BPNSTs). MPNSTs were histologically confirmed while BPNSTs were histologically-proven or with stable clinical and imaging appearance for at least 12 months. Two radiologists assessed imaging characteristics (size, signal intensity, heterogeneity, perilesional edema or enhancement) and the presence or absence of "target sign," on each sequence. A "target sign" was defined as a biphasic pattern of peripheral hyperintensity and homogeneous central hypointensity. Descriptive statistics are reported. Cohen's κ statistic or interclass correlation coefficient (ICC) were used to evaluate interobserver agreement between two observers. Univariate and multiple logistic regression analysis were performed to identify MRI features with predictive values. RESULTS: MPNSTs were larger than BPNSTs (6.3 ± 2.5 cm vs 3.5 ± -2.1 cm, p = 0.0002), had perilesional edema (87%(13/15) vs 18%(6/33), p < 0.0001), heterogeneous enhancement (71%(10/14) vs 13%(4/31), p = 0.0001) and perilesional enhancement (79%(11/14) vs 18%(6/31), p = 0.0001), respectively. The "target sign" was present in: 24%(8/33) BPNSTs vs 0/15 MPNST on T2-FS (p = 0.26); 39%(13/33) BPNSTs vs 20%(3/15) MPNST on DWI using b-value = 50 s/mm2 (p = 0.5); 55%(18/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 400 s/mm2 (p = 0.002); 48%(16/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 800 s/mm2 (p = 0.005) and 64%(21/33) benign vs 0/15 MPNST on ADC mapping(p < 0.0001). By CE-T1 imaging, 32%(10/31) BPNSTs and 7%(1/14) MPNST had a target sign(p = 0.07). The odds of an MPNST in cases with minimum ADC ≤ 1.0 × 10(-3) mm(2)/s are 150 times higher than in cases with ADC > 1.0 × 10(-3). CONCLUSION: In this explorative study, a "target sign" suggests a benign PNST and is more often visible on DWI using high b-values and ADC maps compared with anatomic sequences.
Authors: Lucia Baratto; K Elizabeth Hawk; Lisa States; Jing Qi; Sergios Gatidis; Louise Kiru; Heike E Daldrup-Link Journal: J Nucl Med Date: 2021-10 Impact factor: 10.057
Authors: Enrico Martin; Ritchie T J Geitenbeek; J Henk Coert; David F Hanff; Laura H Graven; Dirk J Grünhagen; Cornelis Verhoef; Walter Taal Journal: Neuro Oncol Date: 2021-04-12 Impact factor: 12.300
Authors: Shivani Ahlawat; K Ina Ly; Laura M Fayad; Michael J Fisher; Andrés J Lessing; Dale J Berg; Johannes M Salamon; Victor-Felix Mautner; Dusica Babovic-Vuksanovic; Eva Dombi; Gordon Harris; Scott R Plotkin; Jaishri Blakeley Journal: Neurology Date: 2021-07-06 Impact factor: 11.800