Literature DB >> 2967988

Wire-loop technique for angioplasty of total iliac artery occlusions.

P A Gaines1, D C Cumberland.   

Abstract

To recanalize occlusions of the iliac artery from an ipsilateral approach, the authors developed a technique in which the guide wire is manipulated through puncture sites in both sides of the groin. This technique was used in four occlusions (three in the common iliac artery and one in the external iliac artery); all occlusions were successfully dilated with balloon catheters. In two cases in which dilation was performed from the contralateral side, the contralateral iliac artery became occluded after the procedure. These occlusions were successfully dilated.

Entities:  

Mesh:

Year:  1988        PMID: 2967988     DOI: 10.1148/radiology.168.1.2967988

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  A simplified pull-through angioplasty technique without a snare device. A technical note.

Authors:  Y Matsumoto; K Nakai; M Tsutsumi; M Iko; H Oishi; H Eto; T Mizokami; K Nii; H Aikawa; K Kazekawa
Journal:  Interv Neuroradiol       Date:  2013-05-21       Impact factor: 1.610

2.  New device for wire and catheter capturing: in vivo experiments and first clinical experience.

Authors:  D Vorwerk; R W Günther; K Schürmann; T Schmitz-Rode
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Sep-Oct       Impact factor: 2.740

3.  Crossover approach with a J-shaped sheath for angioplasty of iliofemoral artery stenoses and occlusions.

Authors:  K Kichikawa; H Uchida; K Nishimine; M Maeda; Y Kubota; H Ohishi
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Mar-Apr       Impact factor: 2.740

4.  Modified crossover and guidewire loop technique for double-balloon angioplasty of the aortic bifurcation.

Authors:  A K Gupta; K Ravimandalam; V R Rao; S Joseph; M Unni; A S Rao
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Mar-Apr       Impact factor: 2.740

5.  Total occlusion of iliac arteries: results of balloon angioplasty.

Authors:  A K Gupta; K Ravimandalam; V R Rao; S Joseph; M Unni; A S Rao; K S Neelkandhan
Journal:  Cardiovasc Intervent Radiol       Date:  1993 May-Jun       Impact factor: 2.740

6.  Bilateral brachial pull-through technique for stenting in a patient with stenosis of the vertebral artery origin: technical case report.

Authors:  N Kusaka; T Tamiya; M Nishiguchi; K Takayama; T Nishiura
Journal:  Neuroradiology       Date:  2007-07-03       Impact factor: 2.804

7.  Balloon-hooking technique for stabilizing a guiding catheter in tortuous supra-aortic vessel: A case report.

Authors:  Kenya Miyoshi; Yosuke Akamatsu; Daigo Kojima; Jun Yoshida; Yasushi Ogasawara; Hiroshi Kashimura; Yoshitaka Kubo; Kuniaki Ogasawara
Journal:  Radiol Case Rep       Date:  2022-08-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.