Literature DB >> 29679396

Validity and application of immunoturbidimetric and enzyme-linked immunosorbent assays for the measurement of adiponectin concentration in ponies.

N J Menzies-Gow1, E J Knowles1, I Rogers2, D I Rendle2.   

Abstract

BACKGROUND: Circulating adiponectin concentrations were lower in ponies with a history of endocrinopathic laminitis and in nonlaminitic ponies that subsequently developed laminitis. The assays used in these studies have been discontinued or are no longer valid.
OBJECTIVES: (1) to determine the validity of immunoturbidimetric (IT) and enzyme linkedimmunosorbent (ELISA) assays for equine total and high molecular weight (HMW) [adiponectin] measurement and (2) to investigate the association between [adiponectin] measured using these assays and endocrinopathic laminitis. STUDY
DESIGN: Method validation and cohort study.
METHODS: Accuracy and precision of IT and ELISA assays for measuring total (TAC) and HMW (HMWAC) [adiponectin] were determined. Using the IT assay, the effects of anti-coagulant and storage temperature were assessed, TAC was measured in previously laminitic (PL) and never laminitic (NL) ponies (n = 6/group). Comparison with a previously validated radioimmunoassay was made in NL ponies (n = 223). Association between TAC and subsequent laminitis development in NL ponies was investigated using univariable logistic regression and ROC curve analysis.
RESULTS: The IT assay was precise and demonstrated good agreement with the previously validated radioimmunoassay. TAC was significantly (P<0.01) lower in PL (mean ± s.d. 8.9 ± 2.9 μg/mL) compared to NL (24.2 ± 11.8 μg/mL) ponies and in NL ponies that developed laminitis within 12 months (median 4.8 μg/mL; IQR 2.65-13.4 μg/mL) compared to those that remained nonlaminitic (19.9 μg/mL; 9.95-31.5 μg/mL). TAC was significantly (P = 0.01) associated with laminitis occurrence within 12 months. Use of the area under the ROC curve to distinguish animals that did and did not develop laminitis showed good accuracy (0.76). None of the ELISA methods validated satisfactorily. MAIN LIMITATIONS: Laminitis risk is based on data from ponies in one region.
CONCLUSIONS: The IT method is suitable for measurement of equine TAC. TAC is lower in ponies with previous or future laminitis. The ELISA methods are not suitable for measurement of equine HMWAC or TAC.
© 2018 EVJ Ltd.

Entities:  

Keywords:  zzm321990EMSzzm321990; adipokine; endocrine; horse; laminitis

Mesh:

Substances:

Year:  2018        PMID: 29679396     DOI: 10.1111/evj.12960

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  3 in total

1.  ECEIM consensus statement on equine metabolic syndrome.

Authors:  Andy E Durham; Nicholas Frank; Cathy M McGowan; Nicola J Menzies-Gow; Ellen Roelfsema; Ingrid Vervuert; Karsten Feige; Kerstin Fey
Journal:  J Vet Intern Med       Date:  2019-02-06       Impact factor: 3.333

2.  Variation in insulin response to oral sugar test in a cohort of horses throughout the year and evaluation of risk factors for insulin dysregulation.

Authors:  Ninja P Karikoski; Justin R Box; Anna K Mykkänen; Veikko V Kotiranta; Marja R Raekallio
Journal:  Equine Vet J       Date:  2021-11-08       Impact factor: 2.692

3.  Interobserver and intraobserver reliability for 2 grading systems for gastric ulcer syndrome in horses.

Authors:  Jessica C Wise; Edwina J A Wilkes; Sharanne L Raidal; Gang Xie; Danielle E Crosby; Josephine N Hale; Kristopher J Hughes
Journal:  J Vet Intern Med       Date:  2020-12-07       Impact factor: 3.175

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.