Literature DB >> 29674029

Direct-immersion single-drop microextraction and in-drop stirring microextraction for the determination of nanomolar concentrations of lead using automated Lab-In-Syringe technique.

Ivana H Šrámková1, Burkhard Horstkotte2, Kateřina Fikarová1, Hana Sklenářová1, Petr Solich1.   

Abstract

Two operational modes for Lab-In-Syringe automation of direct-immersion single-drop microextraction have been developed and critically compared using lead in drinking water as the model analyte. Dithizone was used in the presence of masking additives as a sensitive chromogenic complexing reagent. The analytical procedure was carried out inside the void of an automatic syringe pump. Normal pump orientation was used to study extraction in a floating drop of a toluene-hexanol mixture. Placing the syringe upside-down allowed the use of a denser-than-water drop of chloroform for the extraction. A magnetic stirring bar was placed inside the syringe for homogenous mixing of the aqueous phase and enabled in-drop stirring in the second configuration while resulting in enhanced extraction efficiency. The use of a syringe as the extraction chamber allowed drop confinement and support by gravitational differences in the syringe inlet. Keeping the stirring rates low, problems related to solvent dispersion such as droplet collection were avoided. With a drop volume of 60 µL, limits of detection of 75 nmol L-1 and 23 nmol L-1 were achieved for the floating drop extraction and the in-drop stirring approaches, respectively. Both methods were characterized by repeatability with RSD typically below 5%, quantitative analyte recoveries, and analyte selectivity achieved by interference masking. Operational differences were critically compared. The proposed methods permitted the routine determination of lead in drinking water to be achieved in less than 6 min.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Automation; Direct-immersion single-drop microextraction; Drinking water; In-drop stirring microextraction; Lab-In-Syringe; Lead; dithizone assay

Mesh:

Substances:

Year:  2018        PMID: 29674029     DOI: 10.1016/j.talanta.2018.02.101

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Analytical protocol for determination of endosulfan beta, propham, chlorpyrifos, and acibenzolar-s-methyl in lake water and wastewater samples by gas chromatography-mass spectrometry after dispersive liquid-liquid microextraction.

Authors:  Süleyman Bodur; Cansu Özlü; Büşra Tışlı; Merve Fırat; Dotse Selali Chormey; Sezgin Bakırdere
Journal:  Environ Monit Assess       Date:  2020-03-28       Impact factor: 2.513

2.  Development of a pH-induced dispersive solid-phase extraction method using folic acid combined with dispersive liquid-liquid microextraction: application in the extraction of Cu(II) and Pb(II) ions from water and fruit juice samples.

Authors:  Saeed Mohammad Sorouraddin; Kosar Parvizzad; Mir Ali Farajzadeh
Journal:  Anal Sci       Date:  2022-10-13       Impact factor: 1.967

3.  The Automation Technique Lab-In-Syringe: A Practical Guide.

Authors:  Burkhard Horstkotte; Petr Solich
Journal:  Molecules       Date:  2020-04-01       Impact factor: 4.411

Review 4.  Dynamic Flow Approaches for Automated Radiochemical Analysis in Environmental, Nuclear and Medical Applications.

Authors:  Jixin Qiao
Journal:  Molecules       Date:  2020-03-24       Impact factor: 4.411

Review 5.  Metabolomics-Guided Elucidation of Plant Abiotic Stress Responses in the 4IR Era: An Overview.

Authors:  Morena M Tinte; Kekeletso H Chele; Justin J J van der Hooft; Fidele Tugizimana
Journal:  Metabolites       Date:  2021-07-08

Review 6.  Recent Advancements in the Technologies Detecting Food Spoiling Agents.

Authors:  Reena V Saini; Prachi Vaid; Neeraj K Saini; Samarjeet Singh Siwal; Vijai Kumar Gupta; Vijay Kumar Thakur; Adesh K Saini
Journal:  J Funct Biomater       Date:  2021-11-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.