Literature DB >> 29669954

Micro-CT assessment of comparative radiopacity of adhesive/composite materials in a cylindrical cavity.

Yuta Sumitani1, Hidenori Hamba1,2, Keiki Nakamura1, Alireza Sadr3, Toru Nikaido1, Junji Tagami1.   

Abstract

This study was performed to evaluate the comparative radiopacity of adhesive/resin composite materials in cylindrical cavities using micro-computed X-ray tomography (μCT). The two-step self-etch adhesive systems, Clearfil SE Bond (SE) and FL-Bond II (FL), and flowable resin composites, Beautifil Flow F10 (BF) and Clearfil Majesty ES Flow High (MJ), were used. The radiopacity of bovine tooth structures and restorative materials was measured by μCT. In addition, cylindrical cavities prepared in bovine teeth were restored with the following adhesive/composite combinations: SE-BF, SE-MJ, FL-BF, and FL-MJ. The mean gray values of the composite restorations were calculated. The threshold values of the μCT images were evaluated using the Otsu's thresholding method. The current results show that the comparative radiopacity of the materials and tooth structure varied, which affected distinguishing the μCT images of the composite restorations in the cylindrical cavity. The proper combination of restorative materials should be considered when conducting in vitro μCT assessments of composite restorations.

Entities:  

Keywords:  Bovine teeth; Composite restoration; Radiopacity; μCT

Mesh:

Substances:

Year:  2018        PMID: 29669954     DOI: 10.4012/dmj.2017-310

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  3 in total

1.  How image-processing parameters can influence the assessment of dental materials using micro-CT.

Authors:  Fernanda Ferrari Esteves Torres; Reinhilde Jacobs; Mostafa EzEldeen; Karla de Faria-Vasconcelos; Juliane Maria Guerreiro-Tanomaru; Bernardo Camargo Dos Santos; Mário Tanomaru-Filho
Journal:  Imaging Sci Dent       Date:  2020-06-18

2.  Evaluation of Internal Fit and Marginal Adaptation of Provisional Crowns Fabricated with Three Different Techniques.

Authors:  Jie Wu; Hongjun Xie; Alireza Sadr; Kwok-Hung Chung
Journal:  Sensors (Basel)       Date:  2021-01-22       Impact factor: 3.576

3.  Effects of flowable liners on the shrinkage vectors of bulk-fill composites.

Authors:  Dalia Kaisarly; D Meierhofer; M El Gezawi; P Rösch; K H Kunzelmann
Journal:  Clin Oral Investig       Date:  2021-01-27       Impact factor: 3.573

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.