Xin-Fang Zhang 1 , Qin Qin 2 , Wen-Ye Geng 3 , Chuan-Wei Jiang 1 , Yong Liu 1 , Xiao-Li Liu 4 , Jing Li 4 , Zi-Bing Liu 1,4 . Show Affiliations »
Abstract
OBJECTIVES: Decreased lung function in chronic obstructive pulmonary disease (COPD) is correlated with abnormal excitability of the respiratory centre where orexin neuropeptides from the hypothalamus are responsible for regulating respiration. We hypothesised that improvements in pulmonary function with electroacupuncture (EA) may be related to orexins in a rat model of COPD. METHODS: The COPD model was established by cigarette smoke exposure and lipopolysaccharide injection. Modelled rats received EA at BL13 and ST36 for two weeks, after which lung function was tested. Orexin levels in the hypothalamus and medulla were detected by ELISA, while mRNA/protein expression and localisation of orexins and their receptors were investigated using real time PCR, Western blotting and immunohistochemistry, respectively. RESULTS: The decrease in lung function observed in COPD rats was improved after EA treatment. Orexin levels in the hypothalamus and medulla were significantly higher in COPD rats than in normal rats, but were significantly reduced in the EA-treated group. There was a negative correlation between orexin content and lung function. In the hypothalamus, mRNA and protein expression and immunoreactivity of orexins were significantly higher in the COPD group than in the normal group, but a significant decrease was observed after EA. In the medulla, the expression and immunoreactivity of orexin receptors were significantly higher in the COPD group than in the normal group, but a significant decrease was observed after EA. CONCLUSIONS: The positive effect of EA on pulmonary function in COPD rats may be related to downregulation of orexins and their receptors in the medulla. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
OBJECTIVES: Decreased lung function in chronic obstructive pulmonary disease (COPD) is correlated with abnormal excitability of the respiratory centre where orexin neuropeptides from the hypothalamus are responsible for regulating respiration. We hypothesised that improvements in pulmonary function with electroacupuncture (EA) may be related to orexins in a rat model of COPD. METHODS: The COPD model was established by cigarette smoke exposure and lipopolysaccharide injection. Modelled rats received EA at BL13 and ST36 for two weeks, after which lung function was tested. Orexin levels in the hypothalamus and medulla were detected by ELISA, while mRNA/protein expression and localisation of orexins and their receptors were investigated using real time PCR, Western blotting and immunohistochemistry, respectively. RESULTS: The decrease in lung function observed in COPD rats was improved after EA treatment. Orexin levels in the hypothalamus and medulla were significantly higher in COPD rats than in normal rats , but were significantly reduced in the EA-treated group. There was a negative correlation between orexin content and lung function. In the hypothalamus , mRNA and protein expression and immunoreactivity of orexins were significantly higher in the COPD group than in the normal group, but a significant decrease was observed after EA. In the medulla, the expression and immunoreactivity of orexin receptors were significantly higher in the COPD group than in the normal group, but a significant decrease was observed after EA. CONCLUSIONS: The positive effect of EA on pulmonary function in COPD rats may be related to downregulation of orexins and their receptors in the medulla. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Entities: Chemical
Disease
Gene
Species
Keywords:
electroacupuncture; physiology
Mesh: See more »
Substances: See more »
Year: 2018
PMID: 29669795 DOI: 10.1136/acupmed-2017-011391
Source DB: PubMed Journal: Acupunct Med ISSN: 0964-5284 Impact factor: 2.267