Assessing composite resin wear in primary molars: four-year findings.

W F Vann1, W W Barkmeier, D B Mahler.   

Abstract

Many investigators have reported minimal wear of resin restorations in primary molars. Until recently, quantitative wear assessments have not been reported. The purpose of this investigation was (1) to present and contrast data from two 48-month clinical trials wherein quantitative wear assessments were used to evaluate wear of resin restorations in primary molars, and (2) to compare these results with those using the USPHS method of wear assessment. The data were collected from two different clinical trials. One was conducted at the University of California in San Francisco by Tonn and Ryge (TR Trial). The other was conducted at the University of North Carolina at Chapel Hill by Oldenburg, Vann, and Dilley (OVD Trial). The OVD Trial had a sample size of 45 patients with 106 restorations; the TR Trial had 44 patients with 96 restorations. The restorations in both trials were Class I and II restorations in occlusion. They were placed with the experimental light-cured posterior composite resin F-70, later marketed as Ful-Fill. At baseline, six, 12, 24, 36, and 48 months, restorations were evaluated by two evaluators trained in USPHS criteria as well as by a quantitative method of wear assessment, the standard cast technique as described by Leinfelder. Interstudy comparisons were made by Chi-square tests (USPHS evaluations) and ANOVA (quantitative assessments). The results showed that resin restorations in primary molars exhibited progressive wear with time in service. The rate and quantity of wear were very similar to those seen in permanent posterior teeth over 36 months. Findings agree with previous reports that the USPHS evaluation criteria are insensitive in detecting early wear in primary molars.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2966821     DOI: 10.1177/00220345880670051601

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  6 in total

1.  A 2-year clinical evaluation of stainless steel crowns and composite resin restorations in primary molars under general anaesthesia in China's Guangdong province.

Authors:  K Chen; Q Lei; H Xiong; Y Chen; W Luo; Y Liang
Journal:  Br Dent J       Date:  2018-07-13       Impact factor: 1.626

2.  Effect of thermo-mechanical loading on marginal quality and wear of primary molar crowns.

Authors:  N Krämer; H Rudolph; F Garcia-Godoy; R Frankenberger
Journal:  Eur Arch Paediatr Dent       Date:  2012-08

3.  Clinical evaluation of a self-adhering flowable composite as occlusal restorative material in primary molars: one-year results.

Authors:  Buse Ayse Serin; Iffet Yazicioglu; Ceren Deveci; Muharrem Cem Dogan
Journal:  Eur Oral Res       Date:  2019-09-01

4.  Long-term clinical performance of aesthetic restorations in primary molars: a case report.

Authors:  Luciana Pomarico; Beatriz Gonçalves Neves; Lucianne Cople Maia; Laura Guimarães Primo
Journal:  Case Rep Dent       Date:  2011-09-07

5.  Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns.

Authors:  Jae-Won Choi; Ik-Hyun Bae; Tae-Hwan Noh; Sung-Won Ju; Tae-Kyoung Lee; Jin-Soo Ahn; Tae-Sung Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

Review 6.  Wear of resin composites: Current insights into underlying mechanisms, evaluation methods and influential factors.

Authors:  Akimasa Tsujimoto; Wayne W Barkmeier; Nicholas G Fischer; Kie Nojiri; Yuko Nagura; Toshiki Takamizawa; Mark A Latta; Masashi Miazaki
Journal:  Jpn Dent Sci Rev       Date:  2017-12-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.