Literature DB >> 29667404

Silver Ions as Novel Coreaction Accelerator for Remarkably Enhanced Electrochemiluminescence in a PTCA-S2O82- System and Its Application in an Ultrasensitive Assay for Mercury Ions.

Yan-Mei Lei1, Rui-Xin Wen1, Jia Zhou1, Ya-Qin Chai1, Ruo Yuan1, Ying Zhuo1.   

Abstract

In this work, with the use of Ag(I) ion as robust coreaction accelerator for the enhancement of 3,4,9,10-perylenetetracarboxylic acid-peroxydisulfate (PTCA-S2O82-) system, a highly sensitive solid-state electrochemiluminescence (ECL)-biosensing platform was successfully designed for the detection of mercury ions (Hg2+). Specifically, a long guanine-rich (C-rich) double-stranded DNA (dsDNA) was generated by the target-Hg2+-controlled DNA machine that could amplify the ECL signal of the PTCA-S2O82- system by embedding the Ag(I) ion. Herein, the Ag(I) ion, as a coreaction accelerator, could first react with S2O82- to produce Ag(II) ion and a sulfate radical anion (SO4·-). Then, the accompanying Ag(II) ion could react with H2O to generate the reactive intermediate species (i.e., hydroxyl radical (OH·)), which could further accelerate the reduction of S2O82- to output more SO4·-. Moreover, the recycling of the Ag(I) ion and Ag(II) ion was easily achieved by the electrochemical reaction. Therefore, an avalanche-type reaction was triggered to generate massive amounts of SO4·-, which could react with the luminophore (PTCA) to achieve an extremely strong ECL signal. The ECL mechanism was investigated by ECL and cycle voltammetry (CV) and by the analysis of the fluorescence (FL), ECL, and electron-paramagnetic-resonance (EPR) spectra. As a result, the proposed solid-state ECL-biosensing platform for Hg2+ detection exhibited high sensitivity, with a linear range from 1 × 10-15 to 1 × 10-10 M and a detection limit of 3.3 × 10-16 M. Importantly, this work was the first to utilize a metal ion as a coreaction accelerator and provided a promising approach to improve the sensitivity of target analyses in ECL-biosensing fields.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29667404     DOI: 10.1021/acs.analchem.8b01018

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Advances in electrochemiluminescence co-reaction accelerator and its analytical applications.

Authors:  Haiyan Wang
Journal:  Anal Bioanal Chem       Date:  2021-03-14       Impact factor: 4.142

2.  DNAzyme assisted recycling amplification method for ultrasensitive amperometric determination of lead(II) based on the use of a hairpin assembly on a composite prepared from nitrogen doped graphene, perylenetetracarboxylic anhydride, thionine and gold nanoparticles.

Authors:  Yidan Ma; Chao Yu; Yujie Yu; Jun Chen; Rufei Gao; Junlin He
Journal:  Mikrochim Acta       Date:  2019-09-11       Impact factor: 5.833

3.  Construction of efficient electrochemiluminescence resonance energy transfer sensor based on SnO2/SnS2QDs-Ru@IRMOF-3 composite for sensitive detection of procalcitonin.

Authors:  Dongmiao Qin; Shuo Meng; Yusheng Wu; Zhi Luo; Biyang Deng
Journal:  Mikrochim Acta       Date:  2022-10-21       Impact factor: 6.408

4.  Electrochemiluminescence biosensor for microRNA determination based on AgNCs@MoS2 composite with (AuNPs-Semicarbazide)@Cu-MOF as coreaction accelerator.

Authors:  Fei Li; Minghui Wang; Yunlei Zhou; Huanshun Yin; Shiyun Ai
Journal:  Mikrochim Acta       Date:  2021-02-05       Impact factor: 5.833

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.