Literature DB >> 29667142

Pulmonary cement embolism is not associated with the cause of death in a post-mortem cohort of cement-augmented interventions in the spine.

Sebastian Butscheidt1, Tim Rolvien1, Jakob Ritter2, Axel Heinemann2, Hermann Vogel2, Michael Amling1, Klaus Püschel3.   

Abstract

PURPOSE: Complications of cement-augmented interventions (e.g., kyphoplasty) in the spine include local cement leakage and pulmonary cement embolisms (PCE). This study was conducted to determine their extent in a unique post-mortem cohort.
METHODS: Retrospective analysis of post-mortem whole-body CT scans and review of autopsy results in 29 consecutive cases with cement-augmented interventions in the spine. PCE findings were graded based on cement deposits: grade 0 (no PCE), grade 1 (1-3 PCE), grade 2 (4-6 PCE), and grade 3 (> 6 or branch-shaped PCE). Bone and lung tissue specimens were obtained in representative cases to confirm the findings histologically.
RESULTS: Local cement leakage was detected in 69%: intravenous (34%), intervertebral (31%), intraspinal (14%), and retrograde (17%). Lung sections showed PCE in 52%: grade 0 (48%), grade 1 (31%), grade 2 (10%), and grade 3 (10%). Matching with autopsy findings revealed that none of the cases died due to the impact of PCE.
CONCLUSIONS: The presented data reveal a high frequency of PCE making it a notable finding-especially since not only single but also branch-like embolisms were detected. Thus, it is of great importance that none of the causes of death were related to the impact of PCE. Nevertheless, it is crucial to consider the underlying diseases for increased PCE risk and to apply latest surgical techniques and preventive measures. These slides can be retrieved under Electronic Supplementary material.

Entities:  

Keywords:  Cause of death; Histology; Kyphoplasty; PMMA; Pulmonary cement embolism; Vertebroplasty

Mesh:

Substances:

Year:  2018        PMID: 29667142     DOI: 10.1007/s00586-018-5581-5

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  23 in total

1.  CT evaluation of local leakage of bone cement after percutaneous kyphoplasty and vertebroplasty.

Authors:  In Jae Lee; A Lam Choi; Mi-Yeon Yie; Ji Young Yoon; Eui Yong Jeon; Sung Hye Koh; Dae Young Yoon; Kyung Ja Lim; Hyoung June Im
Journal:  Acta Radiol       Date:  2010-07       Impact factor: 1.990

2.  Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors.

Authors:  Marc J Nieuwenhuijse; Arian R Van Erkel; P D Sander Dijkstra
Journal:  Spine J       Date:  2011-09-01       Impact factor: 4.166

3.  Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

Authors:  I H Lieberman; S Dudeney; M K Reinhardt; G Bell
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

4.  Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy.

Authors:  A Gangi; B A Kastler; J L Dietemann
Journal:  AJNR Am J Neuroradiol       Date:  1994-01       Impact factor: 3.825

5.  Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects.

Authors:  M E Jensen; A J Evans; J M Mathis; D F Kallmes; H J Cloft; J E Dion
Journal:  AJNR Am J Neuroradiol       Date:  1997 Nov-Dec       Impact factor: 3.825

Review 6.  Percutaneous Retrieval of an Embolized Kyphoplasty Cement Fragment From the Pulmonary Artery: A Case Report and Literature Review.

Authors:  Nicole A Lamparello; Vijay Jaswani; Keith DeSousa; Maksim Shapiro; Sandor Kovacs
Journal:  J Radiol Case Rep       Date:  2016-07-31

7.  CT-guided vertebroplasty: analysis of technical results, extraosseous cement leakages, and complications in 500 procedures.

Authors:  Michael Bernhard Pitton; Sascha Herber; Ulrike Koch; Katja Oberholzer; Philip Drees; Christoph Düber
Journal:  Eur Radiol       Date:  2008-06-04       Impact factor: 5.315

8.  Percutaneous vertebroplasty and kyphoplasty for painful vertebral body fractures in cancer patients.

Authors:  Daryl R Fourney; Donald F Schomer; Remi Nader; Jennifer Chlan-Fourney; Dima Suki; Kamran Ahrar; Laurence D Rhines; Ziya L Gokaslan
Journal:  J Neurosurg       Date:  2003-01       Impact factor: 5.115

9.  Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up.

Authors:  A Cotten; F Dewatre; B Cortet; R Assaker; D Leblond; B Duquesnoy; P Chastanet; J Clarisse
Journal:  Radiology       Date:  1996-08       Impact factor: 11.105

10.  Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors.

Authors:  Yeo Ju Kim; Joon Woo Lee; Kun Woo Park; Jin-Seob Yeom; Hee Sun Jeong; Jeong Mi Park; Heung Sik Kang
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more
  4 in total

1.  The Michel Benoist and Robert Mulholland yearly European Spine Journal review: a survey of the "surgical and research" articles in the European Spine Journal, 2018.

Authors:  Robert C Mulholland
Journal:  Eur Spine J       Date:  2019-01-02       Impact factor: 3.134

2.  The impact of incidental pulmonary cement embolism on mortality risk.

Authors:  Hye-Rin Kang; Tae-Hyung Kim; Chun Kee Chung; Chang-Hoon Lee
Journal:  J Thromb Thrombolysis       Date:  2020-04       Impact factor: 2.300

3.  Retrograde Flow Cement Leakage during Kyphoplasty.

Authors:  Kalliopi Alpantaki; Christos Koutserimpas; Nikolaos-Achilleas Arkoudis; Alexander Hadjiapavlou
Journal:  Maedica (Bucur)       Date:  2022-03

4.  Diagnosis of pulmonary cement embolism using only the bone window setting on computed tomography: a case report.

Authors:  Eun Chul Jang; Wookyung Ryu; Seong Yong Woo; Jung Soo Kim; Kyung-Hee Lee; Jeong-Seon Ryu; Seung Min Kwak; Hong Lyeol Lee; Hae-Seong Nam
Journal:  J Int Med Res       Date:  2020-05       Impact factor: 1.671

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.