Split-Depressed Lateral Tibial Plateau Fractures: A Comparison of Augmented Percutaneous Screws Versus Augmented Plate and Screw Construct in a Cadaveric Model.

Richard J Bowles1, Vivek Chadayammuri1, Todd Baldini1, Antonio Brecevich2, Cyril Mauffrey3.   

Abstract

OBJECTIVES: To compare the strength of fixation of percutaneous screw versus plate/screw fixation in a paired cadaver model of OTA 41-B3 (Schatzker type II) split-depression fractures of the lateral tibial plateau.
METHODS: Six matched pairs of cadaveric knees were acquired. An OTA 41-B3 (Schatzker type II) split-depression fracture was created in all specimens using a standardized method. One specimen from each matched pair of knees was fixed with percutaneous screws, and the other was fixed with a plate/screw construct. All specimens underwent augmentation of the central metaphyseal defect with calcium phosphate. Mean residual displacement (depression) was measured on thin-slice high-resolution computed tomography using a standardized methodology following 3 experimental conditions: (1) after they were fixed, before loading; (2) unloaded cycling (simulating postoperative range of motion exercises); and (3) loaded cycling (simulating postoperative weight-bearing). Load to failure was also compared.
RESULTS: After adjustment for baseline measurements, there was no significant difference in mean residual depression of the lateral tibial plateau between treatments groups after unloaded or loaded cyclic testing. Mean residual depression was less than 1 mm in both the treatment groups. Load to failure was statistically equivalent between treatment groups.
CONCLUSIONS: In our cadaveric study, in combination with calcium phosphate augmentation for both methods, percutaneous screw fixation conferred comparable strength of fixation compared with plate/screw constructs for treatment of OTA 41-B3 (Schatzker type II) tibial plateau fractures.

Entities:  

Mesh:

Year:  2018        PMID: 29664880     DOI: 10.1097/BOT.0000000000001177

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  1 in total

1.  Clinical Comparison of the "Windowing" Technique and the "Open Book" Technique in Schatzker Type II Tibial Plateau Fracture.

Authors:  Jichong Ying; Tianming Yu; Jianlei Liu; Dichao Huang; Hailin Yan; Yunqiang Zhuang
Journal:  Orthop Surg       Date:  2022-09-02       Impact factor: 2.279