Literature DB >> 2966442

The systemic activation of platelets by Dacron grafts.

N A Shoenfeld1, R Connolly, K Ramberg, C R Valeri, J Eldrup-Jorgensen, A D Callow.   

Abstract

Dacron (polyester fiber), a stimulus to platelet aggregation in vitro, accumulates platelets to a greater extent in vivo than autogenous artery, polytetrafluoroethylene (PTFE) or human umbilical vein (HUV). We conducted a series of experiments using the ex vivo shunt in the baboon to determine whether or not systemic activation of platelet function was produced by a Dacron graft. Two 5 centimeter segments of 4 millimeter internal diameter graft materials were placed in series in the ex vivo shunt perfused at 25 milliliters per minute flow rate for two and one-half hours. Deposition of autologous Indium 111 labeled platelets was monitored. The ex vivo shunt procedures were divided into two groups, both with PTFE as the proximal graft: one with a distal Dacron graft (n = 21), the second with PTFE or HUV distally (n = 17). In this study, an increase in platelet deposition on the proximal PTFE graft represents systemic platelet activation caused by the distal graft. Increased platelet deposition on PTFE was noted at all time points in the presence of a Dacron graft (p less than 0.05). This property of Dacron has important clinical implications, potentially accelerating the progression of vascular disease, increasing the failure rate of composite grafts and subsequent arterial reconstruction.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2966442

Source DB:  PubMed          Journal:  Surg Gynecol Obstet        ISSN: 0039-6087


  3 in total

1.  In vivo tracking of platelets: circulating degranulated platelets rapidly lose surface P-selectin but continue to circulate and function.

Authors:  A D Michelson; M R Barnard; H B Hechtman; H MacGregor; R J Connolly; J Loscalzo; C R Valeri
Journal:  Proc Natl Acad Sci U S A       Date:  1996-10-15       Impact factor: 11.205

2.  Mechanical features and in vivo imaging of a polymer stent.

Authors:  W J van der Giessen; C J Slager; E J Gussenhoven; H M van Beusekom; R A Huijts; J C Schuurbiers; R A Wilson; P W Serruys; P D Verdouw
Journal:  Int J Card Imaging       Date:  1993-09

3.  A Biohybrid Material With Extracellular Matrix Core and Polymeric Coating as a Cell Honing Cardiovascular Tissue Substitute.

Authors:  Jahnavi Mudigonda; Dongyang Xu; Alan Amedi; Brooks A Lane; Daniella Corporan; Vivian Wang; Muralidhar Padala
Journal:  Front Cardiovasc Med       Date:  2022-03-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.