Literature DB >> 29661564

A new technique for hepatic parenchymal transection using an articulating bipolar 5 cm radiofrequency device: results from the first 100 procedures.

Hideo Takahashi1, Muhammet Akyuz1, Erol Aksoy1, Federico Aucejo1, Cristiano Quintini1, Charles Miller1, John Fung1, Eren Berber2.   

Abstract

BACKGROUND: Parenchymal transection(PT) still remains a challenge in liver resection. The outcomes of the first experience of a novel vessel-sealer for hepatic transection were assessed.
METHODS: A bipolar articulating vessel-sealer (Caiman®, Aesculap Inc., Center Valley, PA) was used in 100 liver resections through both open (OLR) and laparoscopic (LLR) approaches. All data were prospectively collected into an IRB-approved department database, and clinical, surgical and perioperative parameters were analyzed.
RESULTS: Fifty patients underwent OLR and 50 patients underwent LLR. Eighty hepatectomies were performed for malignancy. Median number of tumors was 1, with the largest focus measuring an average of 5.1 cm. Forty-nine of the procedures were major liver resections. Parenchymal transection time was 29.9 ± 3.1 min in OLR and 29.9 ± 3.6 min in LLR. Median estimated blood loss was 300 cc (Inter-quartile range (IQR) 100-575 cc). Median hospital stay was 6 days for open and 3 days for laparoscopic procedures. Ninety-day complication rate was 8% without any mortality. Bile leak rate was 4%. Staplers were used for parenchymal transection in 16 cases.
CONCLUSION: This study introduces a new multifunctional device into the armamentarium of the liver surgeon. In our experience, this device facilitated the parenchymal transection by adding speed and consolidating the amount of instrumentation used in liver resection without increasing complications.
Copyright © 2018 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 29661564     DOI: 10.1016/j.hpb.2018.03.005

Source DB:  PubMed          Journal:  HPB (Oxford)        ISSN: 1365-182X            Impact factor:   3.647


  2 in total

1.  The Italian Consensus on minimally invasive simultaneous resections for synchronous liver metastasis and primary colorectal cancer: A Delphi methodology.

Authors:  Aldo Rocca; Federica Cipriani; Paolo Delrio; Fulvio Calise; Luca Aldrighetti; Giulio Belli; Stefano Berti; Ugo Boggi; Vincenzo Bottino; Umberto Cillo; Matteo Cescon; Matteo Cimino; Francesco Corcione; Luciano De Carlis; Maurizio Degiuli; Paolo De Paolis; Agostino Maria De Rose; Domenico D'Ugo; Fabrizio Di Benedetto; Ugo Elmore; Giorgio Ercolani; Giuseppe M Ettorre; Alessandro Ferrero; Marco Filauro; Felice Giuliante; Salvatore Gruttadauria; Alfredo Guglielmi; Francesco Izzo; Elio Jovine; Andrea Laurenzi; Francesco Marchegiani; Pierluigi Marini; Marco Massani; Vincenzo Mazzaferro; Michela Mineccia; Francesco Minni; Andrea Muratore; Simone Nicosia; Riccardo Pellicci; Riccardo Rosati; Nadia Russolillo; Antonino Spinelli; Gaya Spolverato; Guido Torzilli; Giovanni Vennarecci; Luca Viganò; Leonardo Vincenti
Journal:  Updates Surg       Date:  2021-06-05

2.  Comparison of operative outcomes between monopolar and bipolar coagulation in hepatectomy: a propensity score-matched analysis in a single center.

Authors:  Ryuta Muraki; Yoshifumi Morita; Shinya Ida; Ryo Kitajima; Satoru Furuhashi; Makoto Takeda; Hirotoshi Kikuchi; Yoshihiro Hiramatsu; Atsuko Fukazawa; Takanori Sakaguchi; Mayu Fukushima; Eisaku Okada; Hiroya Takeuchi
Journal:  BMC Gastroenterol       Date:  2022-03-29       Impact factor: 3.067

  2 in total