OBJECTIVE: This study aimed to evaluate image quality (IQ) of virtual monoenergetic images (VMIs) from novel spectral detector computed tomography angiography of the pulmonary arteries and to identify appropriate window settings for each kiloelectron volt level. MATERIALS: Forty consecutive patients were included in this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study.Signal- and contrast-to-noise ratios were calculated within the pulmonary trunk, and pulmonary/lobar/segmental arteries were calculated. The IQ and diagnostic certainty were rated by 2 radiologists on 5-point scales. In addition, they recorded appropriate window settings (center/width) that were linearly modeled against attenuation within the pulmonary trunk to generate generable results. RESULTS: Signal- and contrast-to-noise ratios, IQ, and diagnostic certainty are significantly increased in low-kiloelectron volt VMIs (≤60 keV). Interrater agreement was excellent (ĸ = 0.89). We developed 2 linear models (R: 0.91-0.97 and R: 0.43-0.91, respectively, P ≤ 0.01), that suggest appropriate window settings. CONCLUSIONS: The VMIs from spectral detector computed tomography improve objective and subjective IQ in angiography of the pulmonary arteries, if window settings are adjusted; they can be automatically estimated using reported linear models.
OBJECTIVE: This study aimed to evaluate image quality (IQ) of virtual monoenergetic images (VMIs) from novel spectral detector computed tomography angiography of the pulmonary arteries and to identify appropriate window settings for each kiloelectron volt level. MATERIALS: Forty consecutive patients were included in this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study.Signal- and contrast-to-noise ratios were calculated within the pulmonary trunk, and pulmonary/lobar/segmental arteries were calculated. The IQ and diagnostic certainty were rated by 2 radiologists on 5-point scales. In addition, they recorded appropriate window settings (center/width) that were linearly modeled against attenuation within the pulmonary trunk to generate generable results. RESULTS: Signal- and contrast-to-noise ratios, IQ, and diagnostic certainty are significantly increased in low-kiloelectron volt VMIs (≤60 keV). Interrater agreement was excellent (ĸ = 0.89). We developed 2 linear models (R: 0.91-0.97 and R: 0.43-0.91, respectively, P ≤ 0.01), that suggest appropriate window settings. CONCLUSIONS: The VMIs from spectral detector computed tomography improve objective and subjective IQ in angiography of the pulmonary arteries, if window settings are adjusted; they can be automatically estimated using reported linear models.
Authors: Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann Journal: Br J Radiol Date: 2019-04-09 Impact factor: 3.039
Authors: David Zopfs; Simon Lennartz; Nuran Abdullayev; Thorsten Lichtenstein; Kai Roman Laukamp; Robert Peter Reimer; Christoph Kabbasch; Jan Borggrefe; Marc Schlamann; Victor Neuhaus; Nils Große Hokamp Journal: Quant Imaging Med Surg Date: 2021-08
Authors: Philip Konietzke; Hauke H Steentoft; Willi L Wagner; Jonas Albers; Christian Dullin; Stephan Skornitzke; Wolfram Stiller; Tim F Weber; Hans-Ulrich Kauczor; Mark O Wielpütz Journal: Heliyon Date: 2021-05-26