Literature DB >> 29657518

Influence of light activation of simplified adhesives on the shear bond strength of resin cements to a leucite-reinforced ceramic.

Adilson Yoshio Furuse1, Cassiana Koch Scotti1, Alfredo Llerena-Icochea1, Juliana Fraga Soares Bombonatti1, Gisele Aihara Haragushiku2, Carla Castiglia Gonzaga2.   

Abstract

OBJECTIVE: This study aims to evaluate the influence of the light activation of simplified adhesives on the shear bond strength of resin cements to a glass-ceramic. Three factors were evaluated: (1) cement in two levels (light cured and dual cured); (2) adhesive in two levels (Single Bond 2 and Single Bond Universal), and (3) light activation in two levels (yes or no).
MATERIALS AND METHODS: Thirty-two 1-mm thick slices of a leucite-reinforced glass-ceramic (IPS Empress CAD) were divided into eight groups according to adhesive (Single Bond 2 or Single Bond Universal), cement (AllCem Veneer or AllCem), and light activation of the adhesive before application of the cement (yes or no). Ceramic surfaces were etched for 60 s with 5% hydrofluoric acid, and adhesives were applied. Four cement cylinders were made over each ceramic slice (n = 16) and then submitted to shear bond strength tests. STATISTICAL ANALYSIS: Data were analyzed with three-way ANOVA and Tukey (α = 0.05).
RESULTS: There were significant differences between adhesives (P < 0.0001) and no differences between cements (P = 0.0763) and light activation (P = 0.4385). No interaction effect occurred (P = 0.05). Single Bond 2 showed higher bond strength than Single Bond Universal.
CONCLUSIONS: The light activation of the adhesive before the application of the resin cement did not influence the bond strength.

Entities:  

Keywords:  Ceramics; dental adhesives; shear bond strength

Year:  2018        PMID: 29657518      PMCID: PMC5883473          DOI: 10.4103/ejd.ejd_307_17

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

Dental ceramics are among the main materials due to their well-recognized esthetic properties, precision, biocompatibility, and strength.[123] Despite physical and mechanical properties, the marginal adaption after cementing is still a concern. Acid-sensitive ceramics, such as glass-ceramics, require etching with hydrofluoric acid and a silane-coupling agent, followed by an adhesive for bonding between the resin cement and the ceramics.[456] Although the light activation of the adhesive before cementation is recommended,[78] the fit of the restoration may be impaired if there is adhesive excess. To avoid this problem, an alternative is applying the adhesive without light activating it before applying the resin cement. However, the influence of this nonlight-activation technique on the bond strength of resin-based cements to ceramics still needs evaluation as the compatibility between cements and adhesives is important. The nonlight activation could generate unwanted chemical reactions, depending on type of cement, pH, and hydrophilicity of adhesives.[910111213] Among adhesive systems, universal (multimode or multipurpose) share a wide versatility and high performance due to their composition. The addition of silane-coupling agents could promote adhesion between intrinsically different materials such as resin cements and ceramics. However, the pH of universal adhesives (around 2.7–3.0) could lead to lower compatibility with dual-cured cements when used without activators such as arylsulfinate salts. Considering differences between dual-cured and light-cured resin cements and the potential incompatibility between simplified adhesives and dual-cured cements when adhesives are not light activated before cementation, this study evaluated the influence of light-activating simplified adhesives on the shear bond strength of resin cements to a leucite-reinforced glass-ceramic. Null hypotheses were that there would be no differences between shear bond strengths of (i) two simplified adhesives; (ii) two resin cements; and (iii) two adhesive light-activation protocols.

MATERIALS AND METHODS

Thirty-two 1-mm thick slices obtained from leucite-reinforced ceramic blocks (IPS Empress CAD, Ivoclar Vivadent, Liechtenstein) were embedded in 3/4” Polyvinyl chloride tubes with self-curing acrylic resin and then polished (Ecomet Buehler, Lake Bluff/IL, USA) with sandpapers (granulometry #400 to #600) under water cooling. Slices were etched for 60 s with 5% hydrofluoric acid (Condac Porcelana, FGM, Joinville/SC, Brazil) and divided into eight groups according to the adhesive (two-step etch-and-rinse [Single Bond 2, 3M ESPE, St. Paul/MN, EUA] or one-bottle universal adhesive [Single Bond Universal, 3M ESPE]), resin cement (dual cured [AllCem, FGM] and light cured [AllCem Veneer, FGM]) and light activation of the adhesive (light activation or nonlight activation). Light activation was performed with a light-emitting diode (LED) device (Valo Cordless, Ultradent, South Jordan/UT, USA) with irradiance of 1000 mW/cm2 for the manufacturer's recommended time. For Single Bond 2 groups, a silane-coupling agent (Prosil, FGM) was applied for 1 min, followed by 5-s air drying, before adhesive application. Single Bond Universal was used without silane-coupling agent as follows: application and waiting for 10 s, 10-s solvent evaporation, and 10-s light activation (depending on the group). Materials are described in Table 1.
Table 1

Materials used in this study

Materials used in this study Resin cement cylinders were fabricated with surgical catheters (inner diameter of 1.40 mm and height of 1 mm). Four cylinders per ceramic substrate were made (16 cylinders per group). Resin cements were inserted in the catheters and light activated for 20 s with the same LED device. After 10-min waiting, catheters were removed with #12 scalpel blades to expose cement cylinders. Samples were stored in 37°C deionized water for 24 h and then submitted to the shear bond strength evaluation (Instron, High Wycombe, United Kingdom) using a 0.2-mm wire loop and 0.5 mm/min crosshead speed. A stereomicroscope was used to evaluate the type of failure: adhesive, cohesive in cement, cohesive in ceramic, and mixed. Data were analyzed with three-way ANOVA and Tukey (α = 5%).

RESULTS

Table 2 shows means and standard deviations. There were significant differences between adhesives (P < 0.0001). Higher overall shear bond strength values were observed with Single Bond Universal. There were no differences between resin cements (P = 0.0763) and light-activation protocols (P = 0.4385). Double and triple interactions were not significant (P > 0.05).
Table 2

Shear bond strength means and standard deviations

Shear bond strength means and standard deviations

DISCUSSION

The influence of scanning accuracy of computer-aided design-computer-aided manufacturing systems, dental preparation, and polishing step on marginal and internal adaptation of ceramic systems have been investigated.[14151617] However, the nonlight activation of adhesives during the cementation is an important factor that is closely related to clinical procedures and certainly is a reason of concern among clinicians, especially when universal adhesives are employed. The nonlight activation of adhesives not only would allow reducing operative steps and easing the adaption of prosthetic restorations but also could simplify the cementation by reducing technique sensitivity. For this reason, the present study was designed to address the bond strength using two different categories of simplified adhesives, including a universal one, with light-cured and dual-cured resin cements. According to the results, the only null hypothesis accepted was that there would be no differences between adhesives. Thus, the chemical incompatibility between the evaluated simplified adhesives and the dual-cured resin cement was not significant, which differs from the idea that simplified adhesives are incompatible to dual-cured resin cements.[1819] The present study shows that there was no direct relationship between shear bond strength and resin cements (i.e., light cured and dual cured). The absence of difference between cements could be explained by the fact that the light activation was performed directly over the cement. Thus, it is assumed that most of the reaction happened at the expense of the light activation for both cements because all specimens were light activated immediately rather than waiting for chemical polymerization. It is noteworthy that delaying light activation could impact properties of dual-cured resin cements.[20] Furthermore, in a clinical situation, the ceramics thickness may play a major role on the light activation. Depending on the type, thickness, and color of the ceramic, the radiant exposure may not be enough due to attenuation, compromising the polymerization process.[21222324] In the present study, factors such as thickness and composition of ceramic, light transmittance through the ceramic material, characteristics of the light-curing device, radiant exposure, and concentration of hydrofluoridric acid were not evaluated. For this reason, results of this study could be different not only if the ceramics were interposed but also if many other factors were changed. Regarding the bonding agents, results obtained are in accordance with other studies.[252627] The present study found higher overall shear bond strength for the universal adhesive. This may be explained by the idea that universal adhesives do not share the particularities of other simplified etch-and-rinse systems.[2628] In the case of simplified self-etching adhesives, due to the poorly polymerized oxygen-inhibited layer, the residual acidic resin monomers may react with basic catalytic components such as tertiary amines by bimolecular redox reaction which involves an electron transfer that prevents the generation of free radicals and compromises the chemical reaction.[19] The presence of 10-methacryloyloxydecyl dihydrogen phosphate monomer in Single Bond Universal could explain the best results due to the fact that hydroxyl groups may chemically react with the resin cement and the glass-ceramic phase. Moreover, the incorporation of a silane-coupling agent in this material could improve the interaction with silica through covalent bonds, avoiding the formation of contaminating layers that could weaken bond strength.[29] The shear bond strength method was used instead of a tensile one since it may predict lateral forces and avoid pretesting failures since it is less technique sensitive during specimen preparation. The use of wire loop may lead to a better stress distribution at the bonding area, unlike the severe stress concentration at the load application area by knife-edge chisels.[30] In addition, the small bonding area of cement cylinders decreases the likelihood of a critical flaw being present. Regarding the bond durability and aging degradation, no artificial aging process was performed. For this reason, the results of the present study could be different if long-term water storage, thermocycling, or fatigue methods were employed. Thus, further studies testing long-term durability of these combinations of adhesives and dual-activated cements with nonlight-activated protocol are still needed.

CONCLUSION

According to the results of this study, the non-light-activation protocol of simplified adhesives did not influence the shear bond strength of resin cements to a leucite-reinforced glass-ceramic. The universal adhesive presented better performance on bond strength values when compared to the etch-and-rinse simplified adhesive.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  29 in total

Review 1.  Dental ceramics: current thinking and trends.

Authors:  J Robert Kelly
Journal:  Dent Clin North Am       Date:  2004-04

Review 2.  Ceramic materials in dentistry: historical evolution and current practice.

Authors:  J R Kelly; P Benetti
Journal:  Aust Dent J       Date:  2011-06       Impact factor: 2.291

3.  Effect of Resin Bonded Luting Agents Influencing Marginal Discrepancy in All Ceramic Complete Veneer Crowns.

Authors:  Dhanraj Ganapathy; Anusha Sathyamoorthy; Hemalatha Ranganathan; Karthikeyan Murthykumar
Journal:  J Clin Diagn Res       Date:  2016-12-01

4.  Durability of adhesion between feldspathic ceramic and resin cements: effect of adhesive resin, polymerization mode of resin cement, and aging.

Authors:  Aleska Vanderlei; Sheila Pestana Passos; Mutlu Özcan; Marco Antonio Bottino; Luiz Felipe Valandro
Journal:  J Prosthodont       Date:  2013-01-04       Impact factor: 2.752

5.  Effect of hydrophilicity on the compatibility between a dual-curing resin cement and one-bottle simplified adhesives.

Authors:  Liang Chen; Byoung In Suh
Journal:  J Adhes Dent       Date:  2013-08       Impact factor: 2.359

6.  Immediate bonding properties of universal adhesives to dentine.

Authors:  Miguel Angel Muñoz; Issis Luque; Viviane Hass; Alessandra Reis; Alessandro Dourado Loguercio; Nara Hellen Campanha Bombarda
Journal:  J Dent       Date:  2013-03-14       Impact factor: 4.379

7.  Controlled, prospective, randomized, clinical split-mouth evaluation of partial ceramic crowns luted with a new, universal adhesive system/resin cement: results after 18 months.

Authors:  Vanessa Vogl; Karl-Anton Hiller; Wolfgang Buchalla; Marianne Federlin; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2016-03-12       Impact factor: 3.573

8.  Factors contributing to the incompatibility between simplified-step adhesives and chemically-cured or dual-cured composites. Part III. Effect of acidic resin monomers.

Authors:  Byoung I Suh; Li Feng; David H Pashley; Franklin R Tay
Journal:  J Adhes Dent       Date:  2003       Impact factor: 2.359

Review 9.  Bonding of resin composites to etchable ceramic surfaces - an insight review of the chemical aspects on surface conditioning.

Authors:  J P Matinlinna; P K Vallittu
Journal:  J Oral Rehabil       Date:  2007-08       Impact factor: 3.837

10.  Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements.

Authors:  Patricia Angélica Milani Calgaro; Adilson Yoshio Furuse; Gisele Maria Correr; Bárbara Pick Ornaghi; Carla Castiglia Gonzaga
Journal:  Braz Oral Res       Date:  2013 Sep-Oct
View more
  2 in total

1.  Effect of different surface treatments and multimode adhesive application on the Weibull characteristics, wettability, surface topography and adhesion to CAD/CAM lithium disilicate ceramic.

Authors:  Karina Barbosa Souza; Dayanne Monielle Duarte Moura; Sarah Emille Gomes da Silva; Gabriela Monteiro de Araújo; Rafael de Almeida Spinelli Pinto; Fabíola Pessôa Pereira Leite; Mutlu Özcan; Rodrigo Othávio de Assunção E Souza
Journal:  J Appl Oral Sci       Date:  2020-11-27       Impact factor: 2.698

Review 2.  Assessment of Bonding Effectiveness of Adhesive Materials to Tooth Structure using Bond Strength Test Methods: A Review of Literature.

Authors:  Aminah M El Mourad
Journal:  Open Dent J       Date:  2018-09-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.