Comparison between McMaster and Mini-FLOTAC methods for the enumeration of Eimeria maxima oocysts in poultry excreta.

C Bortoluzzi1, K L Paras2, T J Applegate3, G G Verocai4.   

Abstract

Monitoring Eimeria shedding has become more important due to the recent restrictions to the use of antibiotics within the poultry industry. Therefore, there is a need for the implementation of more precise and accurate quantitative diagnostic techniques. The objective of this study was to compare the precision and accuracy between the Mini-FLOTAC and the McMaster techniques for quantitative diagnosis of Eimeria maxima oocyst in poultry. Twelve pools of excreta samples of broiler chickens experimentally infected with E. maxima were analyzed for the comparison between Mini-FLOTAC and McMaster technique using, the detection limits (dl) of 23 and 25, respectively. Additionally, six excreta samples were used to compare the precision of different dl (5, 10, 23, and 46) using the Mini-FLOTAC technique. For precision comparisons, five technical replicates of each sample (five replicate slides on one excreta slurry) were read for calculating the mean oocyst per gram of excreta (OPG) count, standard deviation (SD), coefficient of variation (CV), and precision of both aforementioned comparisons. To compare accuracy between the methods (McMaster, and Mini-FLOTAC dl 5 and 23), excreta from uninfected chickens was spiked with 100, 500, 1,000, 5,000, or 10,000 OPG; additional samples remained unspiked (negative control). For each spiking level, three samples were read in triplicate, totaling nine reads per spiking level per technique. Data were transformed using log10 to obtain normality and homogeneity of variances. A significant correlation (R = 0.74; p = 0.006) was observed between the mean OPG of the McMaster dl 25 and the Mini-FLOTAC dl 23. Mean OPG, CV, SD, and precision were not statistically different between the McMaster dl 25 and Mini-FLOTAC dl 23. Despite the absence of statistical difference (p > 0.05), Mini-FLOTAC dl 5 showed a numerically lower SD and CV than Mini-FLOTAC dl 23. The Pearson correlation coefficient revealed significant and positive correlation among the four dl (p ≤ 0.05). In the accuracy study, it was observed that the Mini-FLOTAC dl 5 and 23 were more accurate than the McMaster for 100 OPG, and the Mini-FLOTAC dl 23 had the highest accuracy for 500 OPG. The McMaster and Mini-FLOTAC dl 23 techniques were more accurate than the Mini-FLOTAC dl 5 for 5,000 OPG, and both dl of the Mini-FLOTAC were less accurate for 10,000 OPG counts than the McMaster technique. However, the overall accuracy of the Mini-FLOTAC dl 23 was higher than the McMaster and Mini-FLOTAC dl 5 techniques.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Coccidiosis; Diagnostic parasitology; Eimeriosis; Quantitative diagnostic test

Mesh:

Year:  2018        PMID: 29657006     DOI: 10.1016/j.vetpar.2018.02.039

Source DB:  PubMed          Journal:  Vet Parasitol        ISSN: 0304-4017            Impact factor:   2.738


  2 in total

1.  Improving the sensitivity of gastrointestinal helminth detection using the Mini-FLOTAC technique in wild birds.

Authors:  Dante Lobos-Ovalle; Claudio Navarrete; Juan G Navedo; Miguel Peña-Espinoza; Claudio Verdugo
Journal:  Parasitol Res       Date:  2021-08-04       Impact factor: 2.289

Review 2.  Chicken Coccidiosis: From the Parasite Lifecycle to Control of the Disease.

Authors:  Carolina Mesa-Pineda; Jeffer L Navarro-Ruíz; Sara López-Osorio; Jenny J Chaparro-Gutiérrez; Luis M Gómez-Osorio
Journal:  Front Vet Sci       Date:  2021-12-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.