Literature DB >> 29656971

Long-Term Outcomes After Metal-on-Metal Total Hip Arthroplasty With a 28-mm Head: A 17- to 23-Year Follow-Up Study of a Previous Report.

Jun-Ki Moon1, Yeesuk Kim2, Kyu-Tae Hwang2, Jae-Hyuk Yang1, Young-Ha Oh3, Young-Ho Kim1.   

Abstract

BACKGROUND: Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography.
METHODS: A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated.
RESULTS: The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%).
CONCLUSION: MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  metal-on-metal; osteolysis; small head; survivorship; total hip arthroplasty

Mesh:

Substances:

Year:  2018        PMID: 29656971     DOI: 10.1016/j.arth.2018.02.089

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

Review 1.  Recent updates for biomaterials used in total hip arthroplasty.

Authors:  Chang Yong Hu; Taek-Rim Yoon
Journal:  Biomater Res       Date:  2018-12-05

2.  Minimum 15-year results of metasul 28-mm metal-on-metal total hip arthroplasty in patients younger than 50 years of age.

Authors:  Sheng-Yu Jin; Jing-Yao Jin; Joon-Kyoo Kang; Taek-Rim Yoon; Kyung-Soon Park
Journal:  J Orthop Surg Res       Date:  2021-03-25       Impact factor: 2.359

3.  Adverse Tissue Reactions and Metal Ion Behavior After Small-Head Metasul Hip Arthroplasty: A Long-Term Follow-Up Study.

Authors:  Tsunehito Ishida; Toshiyuki Tateiwa; Yasuhito Takahashi; Yohei Nishikawa; Takaaki Shishido; Toshinori Masaoka; Kengo Yamamoto
Journal:  Orthop Surg       Date:  2021-12-15       Impact factor: 2.071

  3 in total