In-plane "superresolution" MRI with phaseless sub-pixel encoding.

Franciszek Hennel1, Rui Tian1, Maria Engel1, Klaas P Pruessmann1.   

Abstract

PURPOSE: Acquisition of high-resolution imaging data using multiple excitations without the sensitivity to fluctuations of the transverse magnetization phase, which is a major problem of multi-shot MRI. THEORY AND METHODS: The concept of superresolution MRI based on microscopic tagging is analyzed using an analogy with the optical method of structured illumination. Sinusoidal tagging is shown to provide subpixel resolution by mixing of neighboring spatial frequency (k-space) bands. It represents a phaseless modulation added on top of the standard Fourier encoding, which allows the phase fluctuations to be discarded at an intermediate reconstruction step. Improvements are proposed to correct for tag distortions due to magnetic field inhomogeneity and to avoid the propagation of Gibbs ringing from intermediate low-resolution images to the final image. The method was applied to diffusion-weighted EPI.
RESULTS: Artifact-free superresolution images can be obtained despite a finite duration of the tagging sequence and related pattern distortions by a field map based phase correction of band-wise reconstructed images. The ringing effect present in the intermediate images can be suppressed by partial overlapping of the mixed k-space bands in combination with an adapted filter. High-resolution diffusion-weighted images of the human head were obtained with a three-shot EPI sequence despite motion-related phase fluctuations between the shots.
CONCLUSION: Due to its phaseless character, tagging-based sub-pixel encoding is an alternative to k-space segmenting in the presence of unknown phase fluctuations, in particular those due to motion under strong diffusion gradients. Proposed improvements render the method practicable in realistic conditions.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  MRI; diffusion imaging; phase sensitivity; spatial encoding; structured illumination; superresolution

Mesh:

Year:  2018        PMID: 29656440     DOI: 10.1002/mrm.27209

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  2 in total

1.  Fast submillimeter diffusion MRI using gSlider-SMS and SNR-enhancing joint reconstruction.

Authors:  Justin P Haldar; Yunsong Liu; Congyu Liao; Qiuyun Fan; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2020-01-10       Impact factor: 4.668

2.  Unbalanced SSFP for super-resolution in MRI.

Authors:  Peter J Lally; Paul M Matthews; Neal K Bangerter
Journal:  Magn Reson Med       Date:  2020-11-17       Impact factor: 3.737

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.