Biphasic Cuirass Ventilation During Anesthesia for Tracheobronchial Stent Insertion or Removal by a Rigid Bronchoscope: A Case Report.

Hideaki Mori1, Atsuko Shono, Ritsuko Hirade, Tetsuro Nikai, Yoji Saito.   

Abstract

Airway management and ventilation during a tracheobronchial stenting procedure are challenging given that mandatory positive pressure ventilation cannot be fully achieved while using a rigid bronchoscope due to leakage from the scope tip. Biphasic cuirass ventilation is a negative pressure ventilation method using an external cuirass fitted to the anterior chest, which could assist in spontaneous breathing and ventilation support. We report 3 successful anesthesia cases in which we could maintain adequate ventilation and oxygenation, supported by biphasic cuirass ventilation, in patients undergoing tracheobronchial stent placement or removal procedures using rigid bronchoscopy.

Entities:  

Year:  2018        PMID: 29652684     DOI: 10.1213/XAA.0000000000000660

Source DB:  PubMed          Journal:  A A Pract        ISSN: 2575-3126


  1 in total

1.  Abdominal Displacement Ventilation: An Effective Intervention for Sedation-Induced Hypoxia.

Authors:  Nikhil Meena; Maggie Macchiarella; Jose Diego Caceres; Thaddeus Bartter