Literature DB >> 29651945

Modeling of a Cyclotron Target for the Production of 11C with Geant4.

Andrea Chiappiniello1, Federico Zagni2, Angelo Infantino3, Sara Vichi4, Gianfranco Cicoria2, Maria Pia Morigi5, Mario Marengo2.   

Abstract

BACKGROUND: In medical cyclotron facilities, 11C is produced according to the 14N(p,α)11C reaction and widely employed in studies of prostate and brain cancers by Positron Emission Tomography. It is known from literature that the 11C-target assembly shows a reduction in efficiency during time, meaning a decrease of activity produced at the end of bombardment. This effect might depend on aspects which are still not completely known.
OBJECTIVE: Possible causes of the loss of performance of the 11C-target assembly were addressed by Monte Carlo simulations.
METHODS: Geant4 was used to model the 11C-target assembly of a GE PETtrace cyclotron. The physical and transport parameters to be used in the energy range of medical applications were extracted from literature data and 11C routine productions. The Monte Carlo assessment of 11C saturation yield was performed varying several parameters such as the proton energy and the angle of the target assembly with respect to the proton beam.
RESULTS: The estimated 11C saturation yield is in agreement with IAEA data at the energy of interest, while it is about 35% greater than the experimental value. A more comprehensive modeling of the target system, including thermodynamic effect, is required. The energy absorbed in the inner layer of the target chamber was up to 46.5 J/mm2 under typical irradiation conditions.
CONCLUSION: This study shows that Geant4 is potentially a useful tool to design and optimize targetry for PET radionuclide productions. Tests to choose the Geant4 physics libraries should be performed before using this tool with different energies and materials. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

Entities:  

Keywords:  Carbon-11; Cyclotron; Geant4; Monte Carlo; PET; electromagnetic interactions; material activation; radiopharmaceutical; target modeling.

Mesh:

Substances:

Year:  2018        PMID: 29651945     DOI: 10.2174/1874471011666180412170219

Source DB:  PubMed          Journal:  Curr Radiopharm        ISSN: 1874-4710


  1 in total

1.  Characterization of the relationship between neutron production and thermal load on a target material in an accelerator-based boron neutron capture therapy system employing a solid-state Li target.

Authors:  Satoshi Nakamura; Hiroshi Igaki; Masashi Ito; Hiroyuki Okamoto; Shie Nishioka; Kotaro Iijima; Hiroki Nakayama; Mihiro Takemori; Shoji Imamichi; Tairo Kashihara; Kana Takahashi; Koji Inaba; Kae Okuma; Naoya Murakami; Yoshihisa Abe; Yuko Nakayama; Mitsuko Masutani; Teiji Nishio; Jun Itami
Journal:  PLoS One       Date:  2019-11-22       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.