Literature DB >> 29643128

Effects of Impella on Coronary Perfusion in Patients With Critical Coronary Artery Stenosis.

Mohammad Alqarqaz1, Mir Basir2, Khaldoon Alaswad2, William O'Neill2.   

Abstract

BACKGROUND: Mechanical circulatory support devices are used to maintain hemodynamic stability during high-risk percutaneous coronary interventions. Little is known on the effects of such devices on coronary hemodynamics in patients with significant coronary stenosis. We sought to investigate whether mechanical circulatory support in the form of Impella (Abiomed Inc, Danvers, MA) can improve coronary hemodynamics in the presence of a critical coronary stenosis. METHODS AND
RESULTS: We examined coronary perfusion pressures and coronary pressure distal to a critical stenosis using a coronary pressure wire in 11 patients (12 coronary lesions) undergoing high-risk percutaneous coronary interventions with the use of mechanical circulatory support. Systemic, ventricular, and coronary hemodynamics were obtained at both minimum and maximum support levels before high-risk percutaneous coronary interventions. All patients had obstructive lesions with angiographically estimated diameter stenosis between 70% and 99% and distal coronary artery pressure to aortic pressure ratios between 0.44 and 0.88. When compared with minimum support, maximum support resulted in a decrease in the left ventricular end-diastolic pressure (27.3±8.6 versus 21.5±5.2 mm Hg; P=0.002) and increases in the mean systemic blood pressure (77.6±13.5 versus 88.2±12.2 mm Hg; P<0.001) and mean distal coronary pressure (51.8±20.2 versus 60.8±18.1 mm Hg; P<0.001). Effective coronary perfusion pressure (mean aortic pressure-left ventricular end-diastolic pressure) significantly increased with maximum support (49.8±15.7 versus 67.2±13.6 mm Hg; P<0.001). Diastolic perfusion pressure (diastolic blood pressure-left ventricular end-diastolic pressure) also significantly increased with maximum support (32.9±13.4 versus 52.0±11.6 mm Hg; P<0.001).
CONCLUSIONS: Mechanical circulatory support with Impella can improve distal coronary pressure and coronary perfusion pressures in the presence of critical coronary stenosis.
© 2018 American Heart Association, Inc.

Entities:  

Keywords:  arterial pressure; blood pressure; coronary vessels; heart; hemodynamics

Mesh:

Year:  2018        PMID: 29643128     DOI: 10.1161/CIRCINTERVENTIONS.117.005870

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  6 in total

1.  Joint EAPCI/ACVC expert consensus document on percutaneous ventricular assist devices.

Authors:  Alaide Chieffo; Dariusz Dudek; Christian Hassager; Alain Combes; Mario Gramegna; Sigrun Halvorsen; Kurt Huber; Vijay Kunadian; Jiri Maly; Jacob Eifer Møller; Federico Pappalardo; Giuseppe Tarantini; Guido Tavazzi; Holger Thiele; Christophe Vandenbriele; Nicolas van Mieghem; Pascal Vranckx; Nikos Werner; Susanna Price
Journal:  Eur Heart J Acute Cardiovasc Care       Date:  2021-06-30

2.  Increased and continuous coronary arterial flow was induced by LV uncoupling condition using combined treatment of a microaxial heart pump and venoarterial extracorporeal membrane oxygenation.

Authors:  Motoko Kametani; Masahiro Yamada; Yoko Horibata; Tomohiro Sakamoto; Takashi Unoki
Journal:  Physiol Rep       Date:  2021-10

3.  Risk Stratification by Coronary Perfusion Pressure in Left Ventricular Systolic Dysfunction Patients Undergoing Revascularization: A Propensity Score Matching Analysis.

Authors:  Ming-Jer Hsieh; Chun-Chi Chen; Dong-Yi Chen; Cheng-Hung Lee; Ming-Yun Ho; Jih-Kai Yeh; Yu-Chang Huang; Yu-Ying Lu; Chieh-Yu Chang; Chao-Yung Wang; Shang-Hung Chang; I-Chang Hsieh
Journal:  Front Cardiovasc Med       Date:  2022-04-14

4.  Impella versus Venoarterial Extracorporeal Membrane Oxygenation for Acute Myocardial Infarction Cardiogenic Shock: A Systematic Review and Meta-Analysis.

Authors:  Riley J Batchelor; Andrew Wheelahan; Wayne C Zheng; Dion Stub; Yang Yang; William Chan
Journal:  J Clin Med       Date:  2022-07-07       Impact factor: 4.964

Review 5.  Effect of Atrioventricular Dyssynchrony on Impella Hemodynamics: Mechanism and Its Clinical Implications.

Authors:  Raj Baljepally; Hassan Tahir
Journal:  Cardiol Res       Date:  2021-07-09

6.  Novel Porcine Model of Coronary Dissection Reveals the Impact of Impella on Dissected Coronary Arterial Hemodynamics.

Authors:  Taro Kariya; Kelly P Yamada; Olympia Bikou; Serena Tharakan; Satoshi Miyashita; Kiyotake Ishikawa
Journal:  Front Cardiovasc Med       Date:  2020-09-15
  6 in total