Literature DB >> 29642228

An observational study of clinical outcomes of everolimus-eluting bioresorbable scaffolds comparing the procedural use of optical coherence tomography against angiography alone.

Stephen Hamshere1, Alex Byrne1, Oliver Guttmann1, Paul Rees1, Christos Bourantas1, Roshan Weerakody1, Andrew Wragg1, Charles Knight1, Anthony Mathur1,2, Daniel A Jones1,2.   

Abstract

OBJECTIVES: The introduction of the bioresorbable vascular scaffold (BVS) has led to new avenues of coronary intervention; however, there have been concerns raised regarding the mechanical properties of BVS and the resulting in-stent thrombosis. We aim to assess whether intracoronary imaging improves outcome in patients following BVS implantation. PATIENTS AND METHODS: All patients undergoing percutaneous coronary intervention using BVS at a single centre between June 2013 and June 2016 were included in this study (n=79). Percutaneous coronary intervention with BVS was performed according to conventional practice: predilatation, postdilatation and intracoronary assessment with optical coherence tomography (OCT) according to operator's preferences. The primary endpoint was Major Adverse Cardiovascular Events (MACE), defined as all-cause mortality, myocardial infarction and revascularization, at 120 days.
RESULTS: Forty-three (54.4%) patients underwent OCT assessment and 36 (45.6%) patients underwent angiography alone post-BVS insertion. There were no significant differences at baseline between both groups; a total of 13 (30.2%) patients who had intracoronary OCT imaging performed underwent further postdilatation after malapposed struts were identified. Although no deaths were observed, there was a significant difference seen in MACE over the follow-up period between OCT and angiography cohorts (4.7 vs. 19.4% respectively; P=0.042). There was a greater number of MACE in low-experienced operators.
CONCLUSION: As visual assessment with angiography has poor specificity for identifying strut malapposition, intracoronary OCT should be undertaken in all patients postinsertion of BVS stents in inexperienced operators to appropriately assess for stent malapposition, and reduce the subsequent risk of MACE.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29642228     DOI: 10.1097/MCA.0000000000000626

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  1 in total

1.  Comparison of clinical outcomes between intravascular optical coherence tomography-guided and angiography-guided stent implantation: A meta-analysis of randomized control trials and systematic review.

Authors:  Yu Jiang; Li-Peng He; Ren Gong; Guang-Tao Lei; Yan-Qing Wu
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.