Literature DB >> 29637637

Single breath-hold 3D cardiac T1 mapping using through-time spiral GRAPPA.

Yong Chen1, Wei-Ching Lo2, Jesse I Hamilton2, Kestutis Barkauskas2, Haris Saybasili3, Katherine L Wright1, Joshua Batesole1, Mark A Griswold1,2, Vikas Gulani1,2, Nicole Seiberlich1,2.   

Abstract

The quantification of cardiac T1 relaxation time holds great potential for the detection of various cardiac diseases. However, as a result of both cardiac and respiratory motion, only one two-dimensional T1 map can be acquired in one breath-hold with most current techniques, which limits its application for whole heart evaluation in routine clinical practice. In this study, an electrocardiogram (ECG)-triggered three-dimensional Look-Locker method was developed for cardiac T1 measurement. Fast three-dimensional data acquisition was achieved with a spoiled gradient-echo sequence in combination with a stack-of-spirals trajectory and through-time non-Cartesian generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. The effects of different magnetic resonance parameters on T1 quantification with the proposed technique were first examined by simulating data acquisition and T1 map reconstruction using Bloch equation simulations. Accuracy was evaluated in studies with both phantoms and healthy subjects. These results showed that there was close agreement between the proposed technique and the reference method for a large range of T1 values in phantom experiments. In vivo studies further demonstrated that rapid cardiac T1 mapping for 12 three-dimensional partitions (spatial resolution, 2 × 2 × 8 mm3 ) could be achieved in a single breath-hold of ~12 s. The mean T1 values of myocardial tissue and blood obtained from normal volunteers at 3 T were 1311 ± 66 and 1890 ± 159 ms, respectively. In conclusion, a three-dimensional T1 mapping technique was developed using a non-Cartesian parallel imaging method, which enables fast and accurate T1 mapping of cardiac tissues in a single short breath-hold.
Copyright © 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Look-Locker method; T1 mapping; cardiac imaging; non-Cartesian parallel imaging

Mesh:

Year:  2018        PMID: 29637637      PMCID: PMC5980781          DOI: 10.1002/nbm.3923

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  36 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Multiple 3D inversion recovery imaging for volume T1 mapping of the heart.

Authors:  A Coniglio; P Di Renzi; G Vilches Freixas; G Della Longa; A Santarelli; R Capparella; B Nardiello; C Loiudice; S Bianchi; M D'Arienzo; L Begnozzi
Journal:  Magn Reson Med       Date:  2012-04-05       Impact factor: 4.668

Review 3.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

4.  Inversion recovery snapshot FLASH MR imaging.

Authors:  A Haase; D Matthaei; R Bartkowski; E Dühmke; D Leibfritz
Journal:  J Comput Assist Tomogr       Date:  1989 Nov-Dec       Impact factor: 1.826

5.  Motion correction for myocardial T1 mapping using image registration with synthetic image estimation.

Authors:  Hui Xue; Saurabh Shah; Andreas Greiser; Christoph Guetter; Arne Littmann; Marie-Pierre Jolly; Andrew E Arai; Sven Zuehlsdorff; Jens Guehring; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

Review 6.  State of the Art: Clinical Applications of Cardiac T1 Mapping.

Authors:  Erik B Schelbert; Daniel R Messroghli
Journal:  Radiology       Date:  2016-03       Impact factor: 11.105

7.  Evaluation of diffuse myocardial fibrosis in heart failure with cardiac magnetic resonance contrast-enhanced T1 mapping.

Authors:  Leah Iles; Heinz Pfluger; Arintaya Phrommintikul; Joshi Cherayath; Pelin Aksit; Sandeep N Gupta; David M Kaye; Andrew J Taylor
Journal:  J Am Coll Cardiol       Date:  2008-11-04       Impact factor: 24.094

8.  T1 mapping of the myocardium: intra-individual assessment of post-contrast T1 time evolution and extracellular volume fraction at 3T for Gd-DTPA and Gd-BOPTA.

Authors:  Nadine Kawel; Marcelo Nacif; Anna Zavodni; Jacquin Jones; Songtao Liu; Christopher T Sibley; David A Bluemke
Journal:  J Cardiovasc Magn Reson       Date:  2012-04-28       Impact factor: 5.364

9.  Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold.

Authors:  Stefan K Piechnik; Vanessa M Ferreira; Erica Dall'Armellina; Lowri E Cochlin; Andreas Greiser; Stefan Neubauer; Matthew D Robson
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-19       Impact factor: 5.364

10.  Extracellular volume fraction mapping in the myocardium, part 2: initial clinical experience.

Authors:  Peter Kellman; Joel R Wilson; Hui Xue; W Patricia Bandettini; Sujata M Shanbhag; Kirk M Druey; Martin Ugander; Andrew E Arai
Journal:  J Cardiovasc Magn Reson       Date:  2012-09-11       Impact factor: 5.364

View more
  5 in total

1.  Self-calibrated interpolation of non-Cartesian data with GRAPPA in parallel imaging.

Authors:  Seng-Wei Chieh; Mostafa Kaveh; Mehmet Akçakaya; Steen Moeller
Journal:  Magn Reson Med       Date:  2019-11-13       Impact factor: 4.668

Review 2.  Cardiac MR: From Theory to Practice.

Authors:  Tevfik F Ismail; Wendy Strugnell; Chiara Coletti; Maša Božić-Iven; Sebastian Weingärtner; Kerstin Hammernik; Teresa Correia; Thomas Küstner
Journal:  Front Cardiovasc Med       Date:  2022-03-03

3.  Free-breathing 3D cardiac T1 mapping with transmit B1 correction at 3T.

Authors:  Paul Kyu Han; Thibault Marin; Yanis Djebra; Vanessa Landes; Yue Zhuo; Georges El Fakhri; Chao Ma
Journal:  Magn Reson Med       Date:  2021-11-23       Impact factor: 4.668

4.  FASt single-breathhold 2D multislice myocardial T1 mapping (FAST1) at 1.5T for full left ventricular coverage in three breathholds.

Authors:  Li Huang; Radhouene Neji; Muhummad Sohaib Nazir; John Whitaker; Phuoc Duong; Fiona Reid; Filippo Bosio; Amedeo Chiribiri; Reza Razavi; Sébastien Roujol
Journal:  J Magn Reson Imaging       Date:  2019-07-24       Impact factor: 5.119

5.  A System for Real-Time, Online Mixed-Reality Visualization of Cardiac Magnetic Resonance Images.

Authors:  Dominique Franson; Andrew Dupuis; Vikas Gulani; Mark Griswold; Nicole Seiberlich
Journal:  J Imaging       Date:  2021-12-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.