Literature DB >> 29635953

Noninvasive, continuous, real-time glucose measurements compared to reference laboratory venous plasma glucose values.

Eran Hadar1,2,3, Rony Chen1,2,3, Yoel Toledano1,2, Kinneret Tenenbaum-Gavish1,2, Yuval Atzmon3, Moshe Hod1,2.   

Abstract

Purpose: Current modalities for glucose monitoring are invasive and inconvenient. The search for a noninvasive technique is still ongoing, without a clinically viable product. The aim of our study was to evaluate the safety and accuracy of a novel non-invasive continuous glucometer - the Wizmi™ device.
Methods: Prospective, observational, controlled clinical trial. We included healthy pregnant women designated to undergo a 3-hour oral glucose tolerance test. Each participant underwent synchronous and simultaneous glucose measurement by venous sampling of plasma glucose and non-invasive glucose by Wizmi device. Primary outcome was the accuracy of the Wizmi device as assessed by comparing between paired measurements, i.e. non-invasive glucose measurements by Wizmi versus standard plasma glucose levels, which were taken at the exact same time.
Results: Thirty-two women underwent oral glucose tolerance test (OGTT), contributing 224 paired glucose measurements. Of the 224 paired measurements, all were within the clinically appropriate zones of the Clarke error grid analysis zones -208 (93%) in Zone A and 16 (7%) in zone B. Mean absolute relative difference of the Wizmi non-invasive glucose versus plasma glucose laboratory reference was 7.23% or 9.66 mg/dl. Overall, for all 224 paired measurements, across all Wizmi glucose ranges, the agreement was 86.6, 92.0, 97.8 and 99.5% for deviations within ±15, 20, 30, 40% (if glucose >80 mg/dl) or mg/dl (if glucose ≤80 mg/dl). Conclusions: Wizmi device is novel non-invasive continuous glucose monitor, safe to use, with overall high accuracy compared to a gold standard reference of plasma glucose.

Entities:  

Keywords:  Diabetes; continuous; glucose; monitoring; non-invasive

Mesh:

Substances:

Year:  2018        PMID: 29635953     DOI: 10.1080/14767058.2018.1463987

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  7 in total

1.  Noninvasive, wearable, and tunable electromagnetic multisensing system for continuous glucose monitoring, mimicking vasculature anatomy.

Authors:  Jessica Hanna; Moussa Bteich; Youssef Tawk; Ali H Ramadan; Batoul Dia; Fatima A Asadallah; Aline Eid; Rouwaida Kanj; Joseph Costantine; Assaad A Eid
Journal:  Sci Adv       Date:  2020-06-10       Impact factor: 14.136

Review 2.  Review of Non-invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone.

Authors:  Maryamsadat Shokrekhodaei; Stella Quinones
Journal:  Sensors (Basel)       Date:  2020-02-25       Impact factor: 3.576

Review 3.  Is Raman the best strategy towards the development of non-invasive continuous glucose monitoring devices for diabetes management?

Authors:  Biagio Todaro; Filippo Begarani; Federica Sartori; Stefano Luin
Journal:  Front Chem       Date:  2022-09-26       Impact factor: 5.545

4.  Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy.

Authors:  Pradeep Kumar Anand; Dong Ryeol Shin; Mudasar Latif Memon
Journal:  Diagnostics (Basel)       Date:  2020-05-07

5.  Low-cost portable microwave sensor for non-invasive monitoring of blood glucose level: novel design utilizing a four-cell CSRR hexagonal configuration.

Authors:  Ala Eldin Omer; George Shaker; Safieddin Safavi-Naeini; Hamid Kokabi; Georges Alquié; Frédérique Deshours; Raed M Shubair
Journal:  Sci Rep       Date:  2020-09-16       Impact factor: 4.379

Review 6.  Hypoglycaemia detection and prediction techniques: A systematic review on the latest developments.

Authors:  Omar Diouri; Monika Cigler; Martina Vettoretti; Julia K Mader; Pratik Choudhary; Eric Renard
Journal:  Diabetes Metab Res Rev       Date:  2021-03-24       Impact factor: 4.876

Review 7.  Exhaled Breath Analysis for Diabetes Diagnosis and Monitoring: Relevance, Challenges and Possibilities.

Authors:  Kaushiki Dixit; Somayeh Fardindoost; Adithya Ravishankara; Nishat Tasnim; Mina Hoorfar
Journal:  Biosensors (Basel)       Date:  2021-11-25
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.