Literature DB >> 29634839

Biological Lenticule Implantation for Correction of Hyperopia: An Ex Vivo Study in Human Corneas.

Iben Bach Damgaard, Anders Ivarsen, Jesper Hjortdal.   

Abstract

PURPOSE: To evaluate changes in corneal tomography after stromal lenticule implantation ex vivo, with respect to the dependency of the lenticule thickness and implantation depth on the corneal curvature and the postoperative biomechanical strength at increased chamber pressure.
METHODS: Twenty-eight human donor corneas underwent pocket implantation of refractive stromal lenticules. Four groups were created by the combination of two implantation depths (110 and 160 µm) and two lenticule thicknesses (95 µm = 4.00 diopters [D], 150 µm = 8.00 D). Sagittal keratometry and total corneal refractive power (TCRP4mm,apex,zone) were obtained for the front and back curvature with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) at chamber pressures of 15 and 40 mm Hg.
RESULTS: The anterior curvature steepening was comparable between the 4.00 D and 8.00 D groups (P > .141), but more pronounced with 110 µm implantation depth (P < .038). The posterior curvature flattened significantly more after implantation of 8.00 D than 4.00 D lenticules (P < .002), but was similar at 110 and 160 µm implantation depths (P > .071). Average ΔTCRP for the 4.00 D and 8.00 D groups was 3.10 ± 0.60 and 5.30 ± 1.66 diopters (D) at 110-µm depth, respectively (P = .003), but 1.99 ± 0.79 and 3.36 ± 1.45 D at 160-µm depth, respectively (P = .066). The relative correction achieved was 66% to 78% at 110-µm depth and 42% to 50% at 160-µm depth, but similar when using 4.00 D and 8.00 D lenticules. Increased chamber pressure caused significant anterior and posterior curvature steepening after implantation in all four groups (P < .001), but not before implantation (P > .632).
CONCLUSIONS: The power of the implanted lenticule must be higher than the intended correction, and customized to the chosen implantation depth. Biomechanical strength seems to decrease after lenticule implantation. [J Refract Surg. 2018;34(4):245-252.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Year:  2018        PMID: 29634839     DOI: 10.3928/1081597X-20180206-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

Review 1.  Femtosecond laser-assisted stromal keratophakia for keratoconus: A systemic review and meta-analysis.

Authors:  Andri K Riau; Hla Myint Htoon; Jorge L Alió Del Barrio; Mario Nubile; Mona El Zarif; Leonardo Mastropasqua; Jorge L Alió; Jodhbir S Mehta
Journal:  Int Ophthalmol       Date:  2021-02-20       Impact factor: 2.031

2.  Comparison of clinical outcome of small-incision lenticule intrastromal keratoplasty and FS-LASIK for correction of moderate and high hyperopia.

Authors:  Li Zhang; Yue-Hua Zhou; Chang-Bin Zhai; Jing Zhang; Yan Zheng
Journal:  Int J Ophthalmol       Date:  2022-05-18       Impact factor: 1.645

3.  Bioengineered Human Stromal Lenticule for Recombinant Human Nerve Growth Factor Release: A Potential Biocompatible Ocular Drug Delivery System.

Authors:  Leonardo Mastropasqua; Mario Nubile; Giuseppina Acerra; Nicola Detta; Letizia Pelusi; Manuela Lanzini; Simone Mattioli; Manuela Santalucia; Laura Pietrangelo; Marcello Allegretti; Harminder S Dua; Jodhbir S Mehta; Assunta Pandolfi; Domitilla Mandatori
Journal:  Front Bioeng Biotechnol       Date:  2022-06-23

Review 4.  Refractive surgery beyond 2020.

Authors:  Marcus Ang; Damien Gatinel; Dan Z Reinstein; Erik Mertens; Jorge L Alió Del Barrio; Jorge L Alió
Journal:  Eye (Lond)       Date:  2020-07-24       Impact factor: 3.775

5.  Corneal remodelling and topography following biological inlay implantation with combined crosslinking in a rabbit model.

Authors:  Iben Bach Damgaard; Yu-Chi Liu; Andri Kartasasmita Riau; Ericia Pei Wen Teo; Min Li Tey; Chan Lwin Nyein; Jodhbir Singh Mehta
Journal:  Sci Rep       Date:  2019-03-14       Impact factor: 4.379

6.  A Modified Small-Incision Lenticule Intrastromal Keratoplasty (sLIKE) for the Correction of High Hyperopia: A Description of a New Surgical Technique and Comparison to Lenticule Intrastromal Keratoplasty (LIKE).

Authors:  Majid Moshirfar; Tirth J Shah; Maliha Masud; Trey Fanning; Steven H Linn; Yasmyne Ronquillo; Phillip C Sr Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2018

Review 7.  Femtosecond laser-assisted implantation of corneal stroma lenticule for keratoconus.

Authors:  Adriano Fasolo; Alice Galzignato; Emilio Pedrotti; Chiara Chierego; Tiziano Cozzini; Erika Bonacci; Giorgio Marchini
Journal:  Int Ophthalmol       Date:  2021-02-24       Impact factor: 2.031