Literature DB >> 29633785

Analysis of fentanyl analogs and novel synthetic opioids in blood, serum/plasma, and urine in forensic casework.

Marykathryn Tynon Moody1, Stephanie Diaz1, Parul Shah1, Donna Papsun1, Barry K Logan1.   

Abstract

In recent years an increasing number of novel opioids have appeared on the illicit drug market and have been linked to the growing opioid crisis in the United States. It is suspected that synthetic-opioid-related deaths are underestimated since many laboratories either use a screening method that is not specific and sensitive enough for these compounds or testing is not performed for fentanyl and its related analogs in general. We describe a method for the analysis of 19 of the most current novel opioid drugs quantitatively in whole blood and serum, and 17 analytes qualitatively in urine using solid phase extraction with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The limit of detection was determined to be at a minimum 0.25 ng/mL for beta-hydroxythiofentanyl, 0.05 ng/mL for butyryl/isobutyrylfentanyl, AH-7921, 2-furanylfentanyl, 4-ANPP, and U-47700; 0.025 ng/mL for MT-45, para-methoxybutyrylfentanyl, 4-methylphenethyl acetyl fentanyl, U-50488, acrylfentanyl, valerylfentanyl, and carfentanil; and 0.0125 ng/mL for para-fluorofentanyl, ortho-fluorofentanyl, para-fluorobutyrylfentanyl/FIBF, and alpha-methylfentanyl. The lower limit of quantitation was determined to be 0.1 ng/mL for all analytes except AH-7921, U-47700, U-50488 which were 0.05 ng/mL and beta-hydroxythiofentanyl which was 0.5 ng/mL. The method was validated successfully according to a Scientific Working Group in Forensic Toxicology (SWGTOX) compliant approach. This method was applied to the analysis of 2758 samples between October 2016 and September 2017. It was determined that 4-ANPP, furanylfentanyl, and carfentanil were the 3 most prevalent fentanyl related compounds detected: 56.1% of cases were positive for 4-ANPP, 44.5% were positive for furanylfentanyl, and 25.2% cases were positive for carfentanil.
Copyright © 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Designer opioids; forensic toxicology; liquid chromatography-mass spectrometry

Mesh:

Substances:

Year:  2018        PMID: 29633785     DOI: 10.1002/dta.2393

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.345


  9 in total

Review 1.  Interpol review of toxicology 2016-2019.

Authors:  Wing-Sum Chan; George Fai Wong; Chi-Wai Hung; Yau-Nga Wong; Kit-Mai Fung; Wai-Kit Lee; Kwok-Leung Dao; Chung-Wing Leung; Kam-Moon Lo; Wing-Man Lee; Bobbie Kwok-Keung Cheung
Journal:  Forensic Sci Int       Date:  2020-05-23       Impact factor: 2.395

2.  Detection of Fentanyl Analogs and Synthetic Opioids in Real Hair Samples.

Authors:  Alberto Salomone; Joseph J Palamar; Rachele Bigiarini; Enrico Gerace; Daniele Di Corcia; Marco Vincenti
Journal:  J Anal Toxicol       Date:  2019-05-01       Impact factor: 3.367

3.  Evaluation of a lateral flow immunoassay for the detection of the synthetic opioid fentanyl.

Authors:  Daniel J Angelini; Tracey D Biggs; Michele N Maughan; Michael G Feasel; Edward Sisco; Jennifer W Sekowski
Journal:  Forensic Sci Int       Date:  2019-04-26       Impact factor: 2.395

Review 4.  Blood concentrations of new synthetic opioids.

Authors:  Piotr Adamowicz; Karolina Nowak
Journal:  Int J Legal Med       Date:  2021-10-22       Impact factor: 2.686

Review 5.  Reports of Adverse Events Associated with Use of Novel Psychoactive Substances, 2017-2020: A Review.

Authors:  Amanda L A Mohr; Barry K Logan; Melissa F Fogarty; Alex J Krotulski; Donna M Papsun; Sherri L Kacinko; Marilyn A Huestis; Jeri D Ropero-Miller
Journal:  J Anal Toxicol       Date:  2022-07-14       Impact factor: 3.220

6.  Testing hair for fentanyl exposure: a method to inform harm reduction behavior among individuals who use heroin.

Authors:  Joseph J Palamar; Alberto Salomone; Rachele Bigiarini; Marco Vincenti; Patricia Acosta; Babak Tofighi
Journal:  Am J Drug Alcohol Abuse       Date:  2019-01-02       Impact factor: 3.829

7.  Improvements in Toxicology Testing to Identify Fentanyl Analogs and Other Novel Synthetic Opioids in Fatal Drug Overdoses, Connecticut, January 2016-June 2019.

Authors:  Heather A Clinton; Shobha Thangada; James R Gill; Amy Mirizzi; Susan B Logan
Journal:  Public Health Rep       Date:  2021 Nov-Dec       Impact factor: 2.792

8.  Determination of 37 fentanyl analogues and novel synthetic opioids in hair by UHPLC-MS/MS and its application to authentic cases.

Authors:  Nan Qin; Min Shen; Ping Xiang; Di Wen; Baohua Shen; Hongxiao Deng; Huosheng Qiang; Fenyun Song; Yan Shi
Journal:  Sci Rep       Date:  2020-07-14       Impact factor: 4.379

Review 9.  Non-fentanyl-derived synthetic opioids emerging during recent years.

Authors:  Koutaro Hasegawa; Kayoko Minakata; Masako Suzuki; Osamu Suzuki
Journal:  Forensic Toxicol       Date:  2022-04-29       Impact factor: 2.541

  9 in total