Literature DB >> 2963143

Radionuclide assessment of bladder outlet obstruction: a noninvasive (1-step) method for measurement of voiding time, urinary flow rates and residual urine.

D Groshar1, O M Embon, A Sazbon, E S Koritny, A Frenkel.   

Abstract

Radionuclide uroflowmetry was performed in 23 patients with bladder outlet obstruction and 29 controls. The parameters evaluated were voiding time, time to peak flow rate, time for 50 per cent emptying, average flow rate, peak flow rate, corrected peak flow rate [peak flow rate/(bladder volume)0.5], ejection fraction of the bladder and post-void residual urine. There was a statistically significant difference between controls and patients with bladder outflow obstruction in each parameter: voiding time 28.2 +/- 9.3 versus 49.2 +/- 26.5 seconds, time to peak flow rate 13 +/- 4.1 versus 19 +/- 12.6 seconds, time to 50 per cent emptying 5.5 +/- 2.4 versus 25.7 +/- 26.9 seconds, average flow rate 9.1 +/- 3.7 versus 4 +/- 2.3 ml. per second, peak flow rate 19.6 +/- 7.6 versus 8.8 +/- 4.1 ml. per second, corrected peak flow rate 1.22 +/- 0.32 versus 0.59 +/- 0.22, ejection fraction 95.3 +/- 3.5 versus 79.7 +/- 17.6, and residual urine 13.1 +/- 13.5 versus 74.1 +/- 135 ml., respectively. The corrected peak flow rate showed the best separation between controls and patients with obstruction. Of the controls 93 per cent had a corrected peak flow rate of 0.87 or greater compared to only 13 per cent of the patients with obstruction. This method involves a single noninvasive procedure that enables determination of voiding parameters related to urinary volume, flow and time, and it avoids the extra examination needed to determine the residual urine.

Entities:  

Mesh:

Year:  1988        PMID: 2963143     DOI: 10.1016/s0022-5347(17)42383-4

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  2 in total

1.  Radionuclide voiding patterns in children with vesicoureteral reflux.

Authors:  Marina Vlajković; Slobodan Ilić; Momcilo Bogićević; Milena Rajić; Lidija Ristić; Vesna Petronijević; Emilija Golubović; Vladisav Stefanović; Vera Artiko
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-01-21       Impact factor: 9.236

2.  Double-blind placebo controlled randomized trial of indomethacin on urodynamic values measured by radionuclide imaging.

Authors:  T K Chaudhuri; S Fink; I C Netto; S K Wilson; P Kolm
Journal:  Clin Auton Res       Date:  1993-02       Impact factor: 4.435

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.