Literature DB >> 29630576

Posture and discomfort assessment in computer users while using touch screen device as compared with mouse-keyboard and touch pad-keyboard.

N Kargar1, A R Choobineh2, M Razeghi3, S Keshavarzi4, N Meftahi3.   

Abstract

BACKGROUND: Touch screen computers require significant arm and hand movements. This can result to body discomfort and biomechanical load in users.
OBJECTIVES: This study was carried out to examine posture and users' discomfort while using touch screen device as compared with mouse-keyboard and touch pad-keyboard.
METHODS: Twenty three (23) students participated in this experimental study. The subjects completed pre-defined tasks in three 15 min trials by means of touch screen, touch pad-keyboard and mouse-keyboard as input devices. Postural angles were measured by Qualisys motion capture system. Body discomfort was assessed by a 10-cm visual analog scale. Rating scale was employed to assess the perception of subjects on the posture of body parts while utilizing the three devices.
RESULTS: There was no significant difference in head inclination when using the three types of devices. Nevertheless, the mean of neck (p = 0.005) and trunk (p < 0.0001) inclinations as well as arm angle (p < 0.0001) while using touch screen, differed significantly from the two other devices and were more deviated from neutral posture. The type of input device was found to have significant effect on the right shoulder (p = 0.017), right elbow (p = 0.031), right wrist/hand (p = 0.004) and whole body discomfort (p = 0.026). Touch screen caused more discomfort in the mentioned regions when compared to the other two devices. Friedman test showed that differences of mean ratings for perceived shoulder and elbow postures in the 3 trials were significant (p = 0.005 and p = 0.011, respectively). Touch screen was the most unfavorable input device based on the subjects' judgment.
CONCLUSION: Touch screen caused more deviated postural angles, increased body discomfort and unfavorable postures.

Entities:  

Keywords:  Motion analysis; data entry device; postural angles

Mesh:

Year:  2018        PMID: 29630576     DOI: 10.3233/WOR-182685

Source DB:  PubMed          Journal:  Work        ISSN: 1051-9815


  2 in total

1.  The Effect of Lockdown Due to the COVID-19 Pandemic on Digital Eye Strain Symptoms Among the General Population: A Cross-Sectional Survey.

Authors:  Mohammad Abusamak; Hatim M Jaber; Hamzeh Mohammad Alrawashdeh
Journal:  Front Public Health       Date:  2022-06-22

2.  Implementation of Mobile Psychological Testing on Smart Devices: Evaluation of a ResearchKit-Based Design Approach for the Implicit Association Test.

Authors:  Tobias Jungnickel; Ute von Jan; Urs-Vito Albrecht
Journal:  Front Digit Health       Date:  2022-03-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.