Displaced femoral neck fractures in patients 60 years of age or younger: results of internal fixation with the dynamic locking blade plate.

J H Kalsbeek1, A D P van Walsum2, J P A M Vroemen3, H M J Janzing4, J T Winkelhorst5, B P Bertelink2, W H Roerdink1.   

Abstract

Aims: The objective of this study was to investigate bone healing after internal fixation of displaced femoral neck fractures (FNFs) with the Dynamic Locking Blade Plate (DLBP) in a young patient population treated by various orthopaedic (trauma) surgeons. Patients and
Methods: We present a multicentre prospective case series with a follow-up of one year. All patients aged ≤ 60 years with a displaced FNF treated with the DLBP between 1st August 2010 and December 2014 were included. Patients with pathological fractures, concomitant fractures of the lower limb, symptomatic arthritis, local infection or inflammation, inadequate local tissue coverage, or any mental or neuromuscular disorder were excluded. Primary outcome measure was failure in fracture healing due to nonunion, avascular necrosis, or implant failure requiring revision surgery.
Results: In total, 106 consecutive patients (mean age 52 years, range 23 to 60; 46% (49/106) female) were included. The failure rate was 14 of 106 patients (13.2%, 95% confidence interval (CI) 7.1 to 19.9). Avascular necrosis occurred in 11 patients (10.4%), nonunion in six (5.6%), and loss of fixation in two (1.9%).
Conclusion: The rate of fracture healing after DLBP fixation of displaced femoral neck fracture in young patients is promising and warrants further investigation by a randomized trial to compare the performance against other contemporary methods of fixation. Cite this article: Bone Joint J 2018;100-B:443-9.

Entities:  

Keywords:  Avascular necrosis; Displaced; Femoral neck fracture; Hip fracture; Internal fixation; Intracapsular hip fracture; Multicentre prospective case series; Osteosynthesis; Rotational stability

Mesh:

Year:  2018        PMID: 29629591     DOI: 10.1302/0301-620X.100B4.BJJ-2016-1098.R3

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  4 in total

1.  Biomechanical evaluation of locked plating fixation for unstable femoral neck fractures.

Authors:  E Bliven; S Sandriesser; P Augat; C von Rüden; S Hackl
Journal:  Bone Joint Res       Date:  2020-06-30       Impact factor: 5.853

2.  Study protocol for the DEFENDD trial: an RCT on the Dynamic Locking Blade Plate (DLBP) versus the Dynamic Hip Screw (DHS) for displaced femoral neck fractures in patients 65 years and younger.

Authors:  J H Kalsbeek; W H Roerdink; P Krijnen; M E van den Akker-van Marle; I B Schipper
Journal:  BMC Musculoskelet Disord       Date:  2020-03-03       Impact factor: 2.362

3.  Radiostereometric analysis of the initial stability of internally fixed femoral neck fractures under differential loading.

Authors:  Sami Finnilä; Niko Moritz; Niko Strandberg; Jessica J Alm; Hannu T Aro
Journal:  J Orthop Res       Date:  2018-10-25       Impact factor: 3.494

4.  Retrospective cohort trial protocol of screw fixation compared with hemiarthroplasty for displaced femoral neck fractures in elderly patients.

Authors:  Boquan Qin; Linxian Cui; Yi Ren; Hui Zhang
Journal:  Medicine (Baltimore)       Date:  2020-09-25       Impact factor: 1.817