Literature DB >> 29627084

One-Lung Flooding Enables Ultrasound-Guided Transthoracic Needle Biopsy of Pulmonary Nodules with High Sensitivity.

Thomas Günter Lesser1, Iver Petersen2, Frank Pölzing3, Frank Wolfram4.   

Abstract

Ultrasound-guided transthoracic needle biopsy (USgTTNB) can only be used for peripheral tumours that contact the pleura. Sonographic accessibility of the entire lung can be achieved using one-lung flooding. In this study, feasibility, sensitivity and complication rate of USgTTNB of lung nodules after one-lung flooding in an ex vivo and in vivo lung tumour model were assessed. USgTTNB was performed ex vivo after one-lung flooding in 10 resected human lung lobes containing carcinoma or metastasis. USgTTNB after one-lung flooding and simulation of a lung nodule was conducted in vivo in 5 animals. Transthoracic sonography and chest X-ray were obtained 30 min after reventilation. The lungs were examined macroscopically and histopathologically. The pathologic diagnosis was confirmed in 85.7% and 100% of tumours after first and second puncture attempts, respectively. The successful puncture rate in vivo was 90%. Neither pneumothorax nor bleeding was observed. One-lung flooding enables USgTTNB of lung nodules with a high sensitivity and minimal risk of complications in a pre-clinical model.
Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  One-lung flooding; Pulmonary nodules; Transthoracic needle biopsy; Ultrasound

Mesh:

Year:  2018        PMID: 29627084     DOI: 10.1016/j.ultrasmedbio.2018.03.003

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Marked safety and high diagnostic yield of freehand ultrasound-guided core-needle biopsies performed by pulmonologists.

Authors:  Evgeni Gershman; Ilya Vaynshteyn; Lev Freidkin; Barak Pertzov; Dror Rosengarten; Mordechai Reuven Kramer
Journal:  Thorac Cancer       Date:  2022-04-26       Impact factor: 3.223

2.  Effects of one-lung flooding on porcine haemodynamics and gas exchange.

Authors:  Thomas Lesser; Frank Wolfram; Conny Braun; Reiner Gottschall
Journal:  Int J Med Sci       Date:  2020-10-23       Impact factor: 3.738

3.  Propensity-score-matching analysis to compare efficacy and safety between 16-gauge and 18-gauge needle in ultrasound-guided biopsy for peripheral pulmonary lesions.

Authors:  Weijun Huang; Jieyi Ye; Yide Qiu; Weiwei Peng; Ninghui Lan; Weizhen Cui; Ting Huang; Yinghui Ou; Yingjia Li
Journal:  BMC Cancer       Date:  2021-04-09       Impact factor: 4.430

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.