Literature DB >> 29623384

Precise, accurate and user-independent blood collection system for dried blood spot sample preparation.

Ricardo Neto1,2, Andrew Gooley2,3, Michael C Breadmore2,4, Emily F Hilder5,6, Florian Lapierre7,8.   

Abstract

An accurate and precise 3 μL blood collection and dispensing system is presented for the preparation of dried blood spot (DBS) samples. Using end-to-end glass capillaries in conjugation with pre-punched DBS pads, a blood micro collection system was developed to eliminate the haematocrit dispersion, widely associated with DBS technology, while providing better levels of accuracy and precision during sample preparation. This methodology is compared to traditional micro-volume blood collection systems, such as a pipette and a digitally controlled analytical syringe. Results showed that % of recovery for the capillary methodology was closer to 100% across the three haematocrit (HCT) levels tested and when prepared by two users (98 to 100% for capillaries, 78 to 104% for pipette and 93 to 97% for digital syringe) attesting a higher accuracy. Additionally, by taking advantage of the capillary action mechanism to collect and dispense autonomously the desired volume of blood onto the DBS pad, coefficients of variation between two individuals were significantly lower than with standard methodologies (capillaries-0.05 to 0.77%, pipette-12.71 to 18.53% and digital syringe-0.72 to 1.77%). This alternate aspiration and dispensing methodology could be used by different users without compromising accuracy or precision when handling low volumes of blood during the pre-analytical steps. Graphical abstract Comparison of novel capillary dispensing methodology for dried blood spot sample preparation with pipette and digital syringe methodologies through accuracy and precision measurements of caffeine.

Entities:  

Keywords:  Blood; Dried blood spot; Glass capillary; Microsampling

Mesh:

Substances:

Year:  2018        PMID: 29623384     DOI: 10.1007/s00216-018-0993-y

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

Review 1.  Use of Dried Blood Spot Specimens to Monitor Patients with Inherited Metabolic Disorders.

Authors:  Stuart J Moat; Roanna S George; Rachel S Carling
Journal:  Int J Neonatal Screen       Date:  2020-03-26

2.  The Double Face of Ketamine-The Possibility of Its Identification in Blood and Beverages.

Authors:  Magdalena Świądro; Paweł Stelmaszczyk; Irena Lenart; Renata Wietecha-Posłuszny
Journal:  Molecules       Date:  2021-02-04       Impact factor: 4.411

Review 3.  Performance of laboratory tests used to measure blood phenylalanine for the monitoring of patients with phenylketonuria.

Authors:  Stuart J Moat; Danja Schulenburg-Brand; Hugh Lemonde; James R Bonham; Cas W Weykamp; Joanne V Mei; Graham S Shortland; Rachel S Carling
Journal:  J Inherit Metab Dis       Date:  2019-10-02       Impact factor: 4.750

4.  Effect of liquid flow by pipetting during medium change on deformation of hiPSC aggregates.

Authors:  Yuma Kato; Takuya Matsumoto; Masahiro Kino-Oka
Journal:  Regen Ther       Date:  2019-04-25       Impact factor: 3.419

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.