Literature DB >> 29622874

Utility of CD157 as a Common Leukocytes Marker for Paroxysmal Nocturnal Hemoglobinuria Screening in a Single Tube Five Color Combination.

Khaliqur Rahman1, Ruchi Gupta1, Shivangi Harankhedkar1, Tanvi Gupta1, Manoj K Sarkar1, Soniya Nityanand1.   

Abstract

To study the utility and advantage of CD157 in the paroxysmal nocturnal hemoglobinuria (PNH) screening along with its ability to replace CD24 and CD14. This was a confirmatory study to analyse the role and advantage of CD157 in a single tube five color combination to identify the PNH clones. A serial tenfold dilution experiments was carried out for sensitivity assessment. Reproducibility was checked in the intra-assay and inter-assay experiments. The results obtained with CD157 based assay were compared with the routinely used single tube six color CD24/CD14 based assay. CD157 showed a high degree of sensitivity at the level of 10-4. PNH positive clone sizes were precise with CVs of inter-assay and intra-assay precision analysis for polymorphs/monocytes ranging from 2.94 to 4.31/2.52 to 8.93, and 0.91 to 3.23/1.65 to 5.33%; respectively. The results were similar to those obtained from CD24/CD14 based assay (R2 > 0.993). There was no false positive or false negative result. CD157 was found better in delineating the type II clones. CD157 can be used as a common PNH leucocyte marker with high degree of sensitivity and precision. It can replace CD24 and CD14 from the currently used assays and thus bring down the cost of PNH screening.

Entities:  

Keywords:  CD157; Flow cytometry (FCM); Paroxysmal nocturnal hemoglobinuria (PNH)

Year:  2017        PMID: 29622874      PMCID: PMC5884987          DOI: 10.1007/s12288-017-0867-z

Source DB:  PubMed          Journal:  Indian J Hematol Blood Transfus        ISSN: 0971-4502            Impact factor:   0.900


  14 in total

1.  Guidelines for the diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria and related disorders by flow cytometry.

Authors:  Michael J Borowitz; Fiona E Craig; Joseph A Digiuseppe; Andrea J Illingworth; Wendell Rosse; D Robert Sutherland; Carl T Wittwer; Stephen J Richards
Journal:  Cytometry B Clin Cytom       Date:  2010-07       Impact factor: 3.058

2.  Normal patterns of expression of glycosylphosphatidylinositol-anchored proteins on different subsets of peripheral blood cells: a frame of reference for the diagnosis of paroxysmal nocturnal hemoglobinuria.

Authors:  Pilar María Hernández-Campo; Julia Almeida; María Luz Sánchez; Mariester Malvezzi; Alberto Orfao
Journal:  Cytometry B Clin Cytom       Date:  2006-03       Impact factor: 3.058

3.  Use of CD157 in FLAER-based assays for high-sensitivity PNH granulocyte and PNH monocyte detection.

Authors:  D R Sutherland; E Acton; M Keeney; B H Davis; A Illingworth
Journal:  Cytometry B Clin Cytom       Date:  2013-08-06       Impact factor: 3.058

4.  Improved detection and characterization of paroxysmal nocturnal hemoglobinuria using fluorescent aerolysin.

Authors:  R A Brodsky; G L Mukhina; S Li; K L Nelson; P L Chiurazzi; J T Buckley; M J Borowitz
Journal:  Am J Clin Pathol       Date:  2000-09       Impact factor: 2.493

5.  The complement-inhibitory activity of CD59 resides in its capacity to block incorporation of C9 into membrane C5b-9.

Authors:  S A Rollins; P J Sims
Journal:  J Immunol       Date:  1990-05-01       Impact factor: 5.422

6.  Resistance of paroxysmal nocturnal hemoglobinuria cells to the glycosylphosphatidylinositol-binding toxin aerolysin.

Authors:  R A Brodsky; G L Mukhina; K L Nelson; T S Lawrence; R J Jones; J T Buckley
Journal:  Blood       Date:  1999-03-01       Impact factor: 22.113

7.  Diagnosing PNH with FLAER and multiparameter flow cytometry.

Authors:  D Robert Sutherland; Nancy Kuek; Jeff Davidson; David Barth; Hong Chang; Erik Yeo; Sylvia Bamford; Ian Chin-Yee; Michael Keeney
Journal:  Cytometry B Clin Cytom       Date:  2007-05       Impact factor: 3.058

8.  Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria.

Authors:  Rodolfo Patussi Correia; Laiz Cameirão Bento; Ana Carolina Apelle Bortolucci; Anderson Marega Alexandre; Andressa da Costa Vaz; Daniela Schimidell; Eduardo de Carvalho Pedro; Fabricio Simões Perin; Sonia Tsukasa Nozawa; Cláudio Ernesto Albers Mendes; Rodrigo de Souza Barroso; Nydia Strachman Bacal
Journal:  Einstein (Sao Paulo)       Date:  2016 Jul-Sep

9.  Inhibition of complement activation on the surface of cells after incorporation of decay-accelerating factor (DAF) into their membranes.

Authors:  M E Medof; T Kinoshita; V Nussenzweig
Journal:  J Exp Med       Date:  1984-11-01       Impact factor: 14.307

10.  Deficient biosynthesis of N-acetylglucosaminyl-phosphatidylinositol, the first intermediate of glycosyl phosphatidylinositol anchor biosynthesis, in cell lines established from patients with paroxysmal nocturnal hemoglobinuria.

Authors:  M Takahashi; J Takeda; S Hirose; R Hyman; N Inoue; T Miyata; E Ueda; T Kitani; M E Medof; T Kinoshita
Journal:  J Exp Med       Date:  1993-02-01       Impact factor: 14.307

View more
  1 in total

1.  CD157 Can Replace CD24 and CD14 in a Single-Tube Flow-Cytometric Assay to Detect Paroxysmal Nocturnal Hemoglobinuria (PNH) Clones on Both Neutrophils and Monocytes: A Prospective Study From North India.

Authors:  Roopam Deka; Hara P Pati; Dinesh Chandra; Prabhu Manivannan; Richa Chauhan; Seema Tyagi; Renu Saxena
Journal:  Cureus       Date:  2022-04-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.