Literature DB >> 29620020

Tetrazolium salts-Pluronic F-127 gels for 3D radiotherapy dosimetry.

Klaudia Kwiatos1, Piotr Maras, Slawomir Kadlubowski, Zbigniew Stempień, Mariusz Dudek, Marek Kozicki.   

Abstract

This work is a follow-up study for a recently-proposed 3D radiochromic gel dosimeter that contains a tetrazolium salt and a physical gel matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127). Several tetrazolium salts were examined in this work, including tetrazolium violet, blue tetrazolium chloride, nitro blue tetrazolium chloride (NBT), tetranitro blue tetrazolium chloride (tNBT) and thiazolyl blue tetrazolium bromide (TBTB). The salt-containing gel dosimeters were compared with the first Pluronic gel composition that contained 2,3,5-triphenyltetrazolium chloride (TTC) as the radiation-sensitive component (dose sensitivity of 0.0023 (Gy cm)-1). The Pluronic gels with NBT and tNBT outperformed the other gels, including the TTC-containing gel, with respect to their dose sensitivity and low dose-response. The NBT gels were found to have better stability over time than tNBT gels. Sensitization of the gels to ionizing radiation was examined by addition of tert-butyl alcohol and sodium formate. The best composition was 0.0818% NBT (1 mM), 25% Pluronic F-127 and 0.136  ×  10-2% sodium formate. This gel dosimeter was insensitive to changes in dose rate for photons of different energies. The mean dose sensitivity amounted to 0.0047  ±  0.1  ×  10-4 (Gy cm)-1. A diversion in the dose-response was observed for the gel irradiated with electrons. Additional characteristics of the NBT gel were a linear-dose range and a dynamic-dose range between  <1 and  ⩾150 Gy and a dose threshold of  <1 Gy. The dose distribution registered for the NBT-Pluronic gel was stable after irradiation for over 7 d with no visible diffusion of the irradiated part, which is analogous to the original TTC-Pluronic gel.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29620020     DOI: 10.1088/1361-6560/aabbb6

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Study of the Optimal Composition and Storage Conditions of the Fricke-XO-Pluronic F-127 Radiochromic Dosimeter.

Authors:  Michał Piotrowski; Piotr Maras; Sławomir Kadłubowski; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-01-27       Impact factor: 3.623

2.  Features of PABIGnx 3D Polymer Gel as an Ionising Radiation Dosimeter.

Authors:  Marek Kozicki; Malwina Jaszczak; Piotr Maras
Journal:  Materials (Basel)       Date:  2022-03-31       Impact factor: 3.623

3.  Study of NBT-Pluronic F-127 Gels as 1D UV Radiation Dosimeters for Measurement of Artificial Light Sources.

Authors:  Elżbieta Sąsiadek-Andrzejczak; Agata Mądrakowska; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-03-23       Impact factor: 3.623

4.  Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy.

Authors:  Piotr Maras; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.