Literature DB >> 29616985

Recording characteristics of electrical impedance-electromyography needle electrodes.

H Kwon1, J F Di Cristina, S B Rutkove, B Sanchez.   

Abstract

OBJECTIVE: Needle EMG remains the standard clinical test for neuromuscular disease (NMD) assessment, but it only characterizes myofiber membrane depolarization. On the other hand, electrical impedance provides non-electrically active structural and compositional data of tissues. Here, we designed a prototype of needle electrode integrating electrical impedance and EMG measurement capabilities, the so-called I-EMG needle electrode. APPROACH: We use finite element method models to study the impedance recording characteristics of I-EMG needle electrodes. The simulated electrical and mechanical design specifications are then manufactured to create a prototype of an I-EMG needle electrode. We pilot these new needle electrodes by conducting in vivo impedance measurements with muscle at rest on healthy wild-type (wt, n  =  5) and muscular dystrophy (mdx, n  =  5) mice. Comparisons between wt and mdx mice are performed using Mann-Whitney test, two-tailed, p  <  0.05. The electrical characterization of the EMG electrode in the developed I-EMG needles was performed in vitro on saline solution and through EMG detection in wt animal at rest and during voluntary contractions.
RESULTS: Muscle impedance demonstrate good repeatability (p  <  0.05 and p  <  0.005 for resistance and reactance at 50 kHz, respectively) and agreement between different I-EMG needles. Impedance data allows us to discriminate between mdx and wt muscle (p  <  0.05 and p  <  0.005 for resistance and reactance at 10 kHz, respectively). EMG broadband noise power and peak amplitude using the I-EMG needle were similar to that of a commercial monopolar EMG needle. EMG recordings using the I-EMG needle measured electrical activity similar to a standard monopolar needle with muscle at rest and during voluntary contraction. SIGNIFICANCE: Needle I-EMG technology may offer the opportunity to enhance the diagnostic capability and quantification of NMD beyond that possible with either impedance or EMG techniques separately. Ultimately, needle I-EMG could serve as a new bedside tool to assess NMD without increasing the complexity or duration of the EMG test.

Entities:  

Mesh:

Year:  2018        PMID: 29616985      PMCID: PMC5997185          DOI: 10.1088/1361-6579/aabb8c

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  17 in total

1.  Electrodiagnostic services in the United States.

Authors:  Timothy R Dillingham; Liliana E Pezzin; J Bradford Rice
Journal:  Muscle Nerve       Date:  2004-02       Impact factor: 3.217

2.  Needle electromyography. Fundamentals, normal and abnormal patterns.

Authors:  David C Preston; Barbara E Shapiro
Journal:  Neurol Clin       Date:  2002-05       Impact factor: 3.806

Review 3.  Needle electromyography: basic concepts and patterns of abnormalities.

Authors:  Devon I Rubin
Journal:  Neurol Clin       Date:  2011-12-29       Impact factor: 3.806

Review 4.  A review of clinical quantitative electromyography.

Authors:  Charles Farkas; Andrew Hamilton-Wright; Hossein Parsaei; Daniel W Stashuk
Journal:  Crit Rev Biomed Eng       Date:  2010

5.  Recording characteristics of electrical impedance myography needle electrodes.

Authors:  H Kwon; S B Rutkove; B Sanchez
Journal:  Physiol Meas       Date:  2017-08-21       Impact factor: 2.833

6.  Electrical properties of commercial concentric EMG electrodes.

Authors:  L J Dorfman; K C McGill; K L Cummins
Journal:  Muscle Nerve       Date:  1985-01       Impact factor: 3.217

7.  Cost of illness for neuromuscular diseases in the United States.

Authors:  Jane Larkindale; Wenya Yang; Paul F Hogan; Carol J Simon; Yiduo Zhang; Anjali Jain; Elizabeth M Habeeb-Louks; Annie Kennedy; Valerie A Cwik
Journal:  Muscle Nerve       Date:  2014-01-28       Impact factor: 3.217

8.  Interrater reliability of the needle examination in lumbosacral radiculopathy.

Authors:  Richard Kendall; Robert A Werner
Journal:  Muscle Nerve       Date:  2006-08       Impact factor: 3.217

9.  Discriminating neurogenic from myopathic disease via measurement of muscle anisotropy.

Authors:  Lindsay P Garmirian; Anne B Chin; Seward B Rutkove
Journal:  Muscle Nerve       Date:  2009-01       Impact factor: 3.217

Review 10.  The electrodiagnostic examination with myopathies.

Authors:  A J Wilbourn
Journal:  J Clin Neurophysiol       Date:  1993-04       Impact factor: 2.177

View more
  9 in total

1.  Performing In Vivo and Ex Vivo Electrical Impedance Myography in Rodents.

Authors:  Marie Mortreux; Janice A Nagy; Haowen Zhong; Dong-Min Sung; Holly A Concepcion; Melanie Leitner; Laura Dalle Pazze; Seward B Rutkove
Journal:  J Vis Exp       Date:  2022-06-08       Impact factor: 1.424

2.  On the measurement of skeletal muscle anisotropic permittivity property with a single cross-shaped needle insertion.

Authors:  Hyeuknam Kwon; Hyoung Churl Park; Albert Cheto Barrera; Seward B Rutkove; Benjamin Sanchez
Journal:  Sci Rep       Date:  2022-05-19       Impact factor: 4.996

3.  Modeling and simulation of needle electrical impedance myography in nonhomogeneous isotropic skeletal muscle.

Authors:  Xuesong Luo; Shaoping Wang; Benjamin Sanchez
Journal:  IEEE J Electromagn RF Microw Med Biol       Date:  2021-06-22

Review 4.  Electrical impedance myography: A critical review and outlook.

Authors:  Benjamin Sanchez; Orjan G Martinsen; Todd J Freeborn; Cynthia M Furse
Journal:  Clin Neurophysiol       Date:  2020-12-03       Impact factor: 3.708

5.  Predicting myofiber cross-sectional area and triglyceride content with electrical impedance myography: A study in db/db mice.

Authors:  Sarbesh R Pandeya; Janice A Nagy; Daniela Riveros; Carson Semple; Rebecca S Taylor; Marie Mortreux; Benjamin Sanchez; Kush Kapur; Seward B Rutkove
Journal:  Muscle Nerve       Date:  2020-10-28       Impact factor: 3.217

6.  Modeling and Reproducibility of Twin Concentric Electrical Impedance Myography.

Authors:  Marti Martinez de Morentin Cardoner; Hyeuknam Kwon; Hilda Victoria Gutierrez Pulido; Janice Nagy; Seward Rutkove; Benjamin Sanchez
Journal:  IEEE Trans Biomed Eng       Date:  2021-09-20       Impact factor: 4.756

7.  Relationships between in vivo surface and ex vivo electrical impedance myography measurements in three different neuromuscular disorder mouse models.

Authors:  Sarbesh R Pandeya; Janice A Nagy; Daniela Riveros; Carson Semple; Rebecca S Taylor; Benjamin Sanchez; Seward B Rutkove
Journal:  PLoS One       Date:  2021-10-29       Impact factor: 3.752

Review 8.  Application of Surface Electromyography in Exercise Fatigue: A Review.

Authors:  Jiaqi Sun; Guangda Liu; Yubing Sun; Kai Lin; Zijian Zhou; Jing Cai
Journal:  Front Syst Neurosci       Date:  2022-08-11

Review 9.  MRI and muscle imaging for idiopathic inflammatory myopathies.

Authors:  Samuel Malartre; Damien Bachasson; Guillaume Mercy; Elissone Sarkis; Céline Anquetil; Olivier Benveniste; Yves Allenbach
Journal:  Brain Pathol       Date:  2021-05       Impact factor: 6.508

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.