Literature DB >> 29616462

Devising a technique for distal anastomosis during total arch replacement using the frozen elephant trunk technique: reverse stepwise anastomosis.

Hidenori Sako1, Hideyuki Tanaka2, Masato Morita2, Tetsushi Takayama2.   

Abstract

Frozen elephant technique is an effective procedure used to repair complex thoracic aortic disease involving the aortic arch and the descending aorta, or to treat aortic dissection. However, the technique often requires some creativity to properly place the stent graft and anastomose the graft to the aorta. We recently used the J Graft FROZENIX® (Japan Lifeline Co., Ltd., Tokyo, Japan) in total arch replacement, and devise a technique for distal anastomosis (called "reverse stepwise anastomosis") that was simple and easy and caused minimal bleeding.

Entities:  

Keywords:  Aneurysm; Aortic arch; Aortic dissection; Aortic surgery; Stent graft

Mesh:

Year:  2018        PMID: 29616462     DOI: 10.1007/s11748-018-0903-4

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  5 in total

1.  Use of cuffed anastomosis in total aortic arch replacement.

Authors:  Katsuhiko Oda; Hiroji Akimoto; Masaki Hata; Junetsu Akasaka; Kazuhiro Yamaya; Atsushi Iguchi; Koichi Tabayashi
Journal:  Ann Thorac Surg       Date:  2003-09       Impact factor: 4.330

2.  Total arch replacement using a stepwise distal anastomosis for arch aneurysms with distal extension.

Authors:  Hitoshi Ogino; Motomi Ando; Hiroaki Sasaki; Kenji Minatoya
Journal:  Eur J Cardiothorac Surg       Date:  2006-01-11       Impact factor: 4.191

3.  New graft-implanting method for thoracic aortic aneurysm or dissection with a stented graft.

Authors:  M Kato; K Ohnishi; M Kaneko; T Ueda; D Kishi; T Mizushima; H Matsuda
Journal:  Circulation       Date:  1996-11-01       Impact factor: 29.690

4.  A new device as an open stent graft for extended aortic repair: a multicentre early experience in Japan.

Authors:  Naomichi Uchida; Akira Katayama; Shinichi Higashiue; Motomi Shiono; Mitsumasa Hata; Kazutomo Minami; Kazuo Yamanaka; Shinji Miyamoto; Yoshiki Sawa; Toru Kuratani; Masaaki Kato
Journal:  Eur J Cardiothorac Surg       Date:  2015-09-18       Impact factor: 4.191

5.  Frozen Elephant Trunk: a technique which can be offered in complex pathology to fix the whole aorta in one setting.

Authors:  John Kokotsakis; Vania Anagnostakou; Theodoros Kratimenos; Hutan Ashrafian; Thanos Athanasiou
Journal:  J Cardiothorac Surg       Date:  2011-05-08       Impact factor: 1.637

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.