Buttock Lifting Using Elastic Thread (Elasticum®) with a New Classification of Gluteal Ptosis.

Chang Hyun Oh1, Seung Bin Jang2, Chang Min Kang2, Jeong Su Shim3.   

Abstract

PURPOSE: Conventional buttock lifting is invasive, so it is difficult to recommend it to patients especially to those who do not have severe gluteal ptosis. In addition, the gluteal area is a large area change among the joints. Therefore, this surgery can cause pain during hip flexion after lifting using a conventional thread. The authors report on buttock lifting using an elastic thread with high satisfaction from patients.
METHODS: From July 2016 to June 2017, 60 patients were enrolled in this study. The degree of gluteal ptosis was graded from Grade 0 to Grade 6. All patients underwent lifting of both buttocks using Elasticum®. We drew a circle along the outer edge of the buttock and another small circle inside the first circle. A stab incision was done at 5 points (A, B, C, C', and D), and then according to the circle, lifting was done. Postoperative grade changes and complications were evaluated. RESULT: Grades 2-5 were lifted to at least Grade 2 after surgery, but Grade 6 was at most Grade 3 (14.2%), with 85.8% of these to either Grade 5 or Grade 6. Seven patients (11.67%) complained of postoperative pain, and 6 patients (10.00%) showed skin dimpling or creases 10 days after surgery, all of which disappeared at 1 month after surgery.
CONCLUSION: Buttock lifting with elastic thread is effective in pre-ptosis to moderate gluteal ptosis. Because of the elasticity of the thread, postoperative pain is low on hip flexion, so the lifting is done naturally. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Entities:  

Keywords:  Buttock rejuvenation; Elastic thread; Thread lift

Mesh:

Year:  2018        PMID: 29610954     DOI: 10.1007/s00266-018-1124-z

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  3 in total

1.  Biomechanical Properties and Biocompatibility of a Non-Absorbable Elastic Thread.

Authors:  Yeji Choi; Moonseok Kang; Moon Seop Choi; Jennifer Kim Song; Eugene Lih; Deahyung Lee; Hong-Hee Jung
Journal:  J Funct Biomater       Date:  2019-11-16

2.  Difficulty of Severe Post-liposuction Infragluteal Deformity Correction With Autologous Fat Transplantation: A Case Report.

Authors:  Mingzi Yang; Yunpeng Gu; Jingjing Sun; Qianwen Lv; Yue Qi; Ji Jin; Zhenjun Liu; Guie Ma
Journal:  Front Surg       Date:  2022-02-07

3.  Elastic thread modified minimal access cranial suspension lift for lower and middle third facial rejuvenation.

Authors:  Nanze Yu; Panxi Yu; Zhifei Liu; Jeongmok Cho; Wenchao Zhang; Yutong Liu; Lin Zhu; Ang Zeng; Loubin Si; Fei Long; Yiding Xiao; Xiaojun Wang
Journal:  Medicine (Baltimore)       Date:  2020-03       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.