Mu Young Shin1, Jong Soo Park2, Hae Dong Park1, Jihye Lee2.
Abstract
BACKGROUND: Exposure to sustained high concentrations of HCFC-123 is known to be hepatotoxic. We report two simultaneous cases of toxic hepatitis related to exposure to 2,2-dichloro-1,1,1-trifluoroethane (HCFC-123), a common refrigerant, at a Korean fire extinguisher manufacturing facility. CASEEntities:
Keywords: 2,2-dichloro-1,1,1-trifluoroethane; Drug-induced liver injury; Fire extinguisher manufacturing facility; HCFC-123; Toxic hepatitis
Year: 2018 PMID: 29610668 PMCID: PMC5872401 DOI: 10.1186/s40557-018-0231-2
Source DB: PubMed Journal: Ann Occup Environ Med ISSN: 2052-4374
Progression of patient Aa
| Day 3 | Day 4 | Day 6b | Day 9 | Reference range | |
|---|---|---|---|---|---|
| AST (IU/L) | 2491 | 3108 | 302 | 117 | 0–40 |
| ALT (IU/L) | 2355 | 3265 | 1708 | 662 | 0–40 |
| ALP (IU/L) | 125 | 139 | 144 | 165 | 30–115 |
| Total bilirubin (mg/dL) | 3.4 | 3.3 | 4.0 | 1.9 | 0.2–1.2 |
| GGT (IU/L) | 102 | 96 | – | – | 11–63 |
ALT alanine aminotransferase, ALP alkaline phosphatase, AST aspartate aminotransferase, GGT gamma-glutamyl transferase
aDischarged and returned home on day 10
bGGT was not measured on days 6 and 9
Progression of patient Ba
| On admission | Day 3b | Day 4 | Day 6 | Day 11 | Reference range | |
|---|---|---|---|---|---|---|
| AST (IU/L) | 1551 | 13,537 | 16,152 | 5557 | 352 | 0–40 |
| ALT (IU/L) | 1259 | 7115 | 8245 | 4048 | 409 | 0–40 |
| ALP (IU/L) | 74 | 85 | 170 | 361 | 341 | 30–115 |
| Total bilirubin (mg/dL) | 1.59 | 3.6 | 6.8 | 10.6 | 34.1 | 0.2–1.2 |
| GGT (IU/L) | 154 | 155 | 146 | 100 | 39 | 11–63 |
ALT alanine aminotransferase, ALP alkaline phosphatase, AST aspartate aminotransferase, GGT gamma-glutamyl transferase
aPronounced dead in the early morning of day 12
bThe patient was transferred to a different hospital on day 3
Eight-hour time-weighted average exposure level assessment for HCFC-123
| Worker | Raw material pumping | Automatic charge line | Exposure standard | |||
|---|---|---|---|---|---|---|
| Exposure concentration | Time measured | Exposure concentration | Time measured | TWA | ||
| (ppm) | (min) | (ppm) | (min) | (ppm) | ||
| 1 | 20.7 | 73 | 91.6 | 89 | 20.1 | 50 ppm (AIHA) 10 ppm (JSOH) |
| 2a | – | 115.6 | 87 | 20.9 | ||
| 3 | – | 71.8 | 131 | 19.6 | ||
| 4 | – | 69.5 | 132 | 19.1 | ||
AIHA American Industrial Hygiene Association, JSOH Japan Society for Occupational Health, TWA time-weighted average
aA hyphen means that it was not measured
Short-term and area exposure level assessment of HCFC-123
| Valve assembly | Nitrogen charging | Exposure standard | |||
|---|---|---|---|---|---|
| Exposure concentration | Time measured | Exposure concentration | Time measured | ||
| (ppm) | (min) | (ppm) | (min) | ||
| Short-term exposure | 149.3–193.4 | 15 | 114.6–114.9 | 15 | None |
| Area exposure | 58.3–187.2 | 75–90 | 75.5–112.3 | 90–92 | |