Literature DB >> 29609166

In-vitro model for assessing glucose diffusion through skin.

Sana Ullah1, Fadi Hamade2, Urte Bubniene3, Johan Engblom1, Arunas Ramanavicius3, Almira Ramanaviciene4, Tautgirdas Ruzgas5.   

Abstract

Pig ear skin membrane-covered glucose biosensor based on oxygen electrode has been assessed as a tool to evaluate glucose penetration through skin in-vitro. For this, glucose oxidase (GOx) was immobilised on oxygen electrode and covered with the skin membrane. Exposing this electrode to the solution of glucose resulted in glucose penetration though skin membrane, its oxidation catalysed by GOx, consumption of O2 and decrease of the current of the oxygen electrode. By processing the biosensor responses to glucose, we found that glucose penetration through 250 µm thick skin membrane is slow; 90% of steady-state current response was reached in 32( ± 22) min. Apparent diffusion coefficient for glucose in skin was found to be equal to 0.15( ± 0.07)* 10-6 cm2 s-1. This value is 45 times lower than glucose diffusion coefficient in water. Tape-stripping of stratum corneum (SC) allows considerably faster glucose penetration. The electrodes covered with tape-stripped skin reached 90% of steady-state current response in 5.0(± 2.7) min. The theoretical estimate of glucose flux through SC was considered exploiting four-pathway theory of transdermal penetration. Theoretical flux values were more that three orders lower than measured experimentally. This high discrepancy might indicate that glucose penetration through healthy human skin could be even slower, allowing much lower flux, than it was found in our study for skin membranes from pig ears.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Attachable; Epidermal; Glucose biosensor; Skin; Topical

Mesh:

Substances:

Year:  2018        PMID: 29609166     DOI: 10.1016/j.bios.2018.03.039

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  The Impact of Glucose Oxidase Immobilization on Dendritic Gold Nanostructures on the Performance of Glucose Biosensors.

Authors:  Laura Sakalauskiene; Anton Popov; Asta Kausaite-Minkstimiene; Arunas Ramanavicius; Almira Ramanaviciene
Journal:  Biosensors (Basel)       Date:  2022-05-10

2.  Microbially competent 3D skin: a test system that reveals insight into host-microbe interactions and their potential toxicological impact.

Authors:  Lisa Lemoine; Ralf Dieckmann; Sascha Al Dahouk; Szilvia Vincze; Andreas Luch; Tewes Tralau
Journal:  Arch Toxicol       Date:  2020-07-17       Impact factor: 5.153

Review 3.  Charge Transfer and Biocompatibility Aspects in Conducting Polymer-Based Enzymatic Biosensors and Biofuel Cells.

Authors:  Simonas Ramanavicius; Arunas Ramanavicius
Journal:  Nanomaterials (Basel)       Date:  2021-02-02       Impact factor: 5.076

4.  Visualisation of H2O2 penetration through skin indicates importance to develop pathway-specific epidermal sensing.

Authors:  Skaidre Jankovskaja; Anaïs Labrousse; Léa Prévaud; Bo Holmqvist; Anders Brinte; Johan Engblom; Melinda Rezeli; György Marko-Varga; Tautgirdas Ruzgas
Journal:  Mikrochim Acta       Date:  2020-11-13       Impact factor: 5.833

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.