Literature DB >> 29608892

Evaluation of the LIA-ANA-Profile-17S for the detection of autoantibodies to nuclear antigens.

Ahram Yi1, Chang-Hoon Lee1, Hee-Won Moon2, Hanah Kim1, Mina Hur1, Yeo-Min Yun1.   

Abstract

OBJECTIVES: The diagnostic tests for autoimmune disease include screening for autoantibodies for nuclear antigens (ANA) and antibodies against extractable nuclear antigens (ENA). Using the line immunoassay (LIA) method, various kinds of ENA antibodies can be detected simultaneously. We evaluated the performance of the newly launched LIA-ANA-Profile-17S (Shenzhen YHLO Biotech, Shenzhen, China) as compared to a conventional LIA kit.
METHODS: Residual samples were collected from 200 patients who had been tested for ANA using indirect immunofluorescence. The LIA-ANA-Profile-17S was compared to the EuroLine ANA (Euroimmun, Oberlausitz, Germany) for the analysis of 17 different autoantibodies. The concordance rate and agreement between assays were determined. Samples showing discrepancies between the LIA-ANA-Profile-17S and EuroLine tests were further examined through additional analysis.
RESULTS: The overall agreement was moderate (kappa = 0.759, 95% CI = 0.712-0.805). Agreement between assays ranged from weak to almost perfect, except for those tests targeting nucleosomes, histones, and PM-Scl. Of the 57 disparate results between LIA-ANA-Profile-17S and EuroLine, 38 (66.7%) samples tested positive under an additional assay, showing variable patterns between types of autoantibodies. The positive rate of each autoantibody between LIA-ANA-Profile-17S and EuroLine did not differ significantly, except for anti-nucleosome and anti-histone assays in samples from patients diagnosed with systemic lupus erythematosus (P = 0.004 and 0.001, respectively).
CONCLUSIONS: Compared to those from the conventional EuroLine assay, the LIA-ANA-Profile-17S results showed variable agreement in samples showing different prevalence of each autoantibody. The most frequently detected antibodies showed almost perfect agreement. The LIA-ANA-Profile-17S could play a role in the diagnosis of systemic autoimmune disease in ANA-positive samples.
Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ENA; EuroLine; LIA-ANA-profile-17S; Line immunoassay

Mesh:

Substances:

Year:  2018        PMID: 29608892     DOI: 10.1016/j.clinbiochem.2018.03.020

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  3 in total

1.  Comparison study of bead-based and line-blot multiplex ANA immunoassays in the diagnosis of systemic autoimmune rheumatic diseases.

Authors:  Weiru Yuan; Hua Cao; Weiping Li; Xinyi Wu; Jie Zheng
Journal:  Clin Rheumatol       Date:  2021-10-09       Impact factor: 2.980

2.  Analytical and clinical performance of different platforms simultaneously detecting 15 antinuclear antibodies.

Authors:  Yan Qin; Chunxue Fan; Yanlin Wang; Min Feng; Zhaojun Liang; Xiangcong Zhao; Chong Gao; Jing Luo
Journal:  J Clin Lab Anal       Date:  2022-06-16       Impact factor: 3.124

3.  Comparison of antinuclear antibody profiles obtained using line immunoassay and fluorescence enzyme immunoassay.

Authors:  Jaehyeok Jang; Sinyoung Kim; Hyon-Suk Kim; Kyung-A Lee; Jungyong Park; Younhee Park
Journal:  J Int Med Res       Date:  2021-06       Impact factor: 1.671

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.